𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Indirect atomic absorption spectrometric determination of perchlorate by liquid-liquid extraction in a flow-injection system

✍ Scribed by M. Gallego; M. Valcárcel


Publisher
Elsevier Science
Year
1985
Tongue
English
Weight
571 KB
Volume
169
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


The determination is based on the continuous liquid-liquid extraction of the copper(I)/ 6-methylpicolinealdehyde azine/perchlorate ion-pair into 4-methyl-2-pentanone in a flowinjection manifold. The organic extract fills a loop of an injector situated in an integrated feed system of an atomic absorption spectrometer. Measurement of the copper atomic absorption signal from the organic phase allows the indirect determination of 0.1-5 Mg ml-' perchlorate, giving a 3-fold increase in sensitivity over the conventional spectrophotometric method. The detection limit is 70 ng ml-l. The sampling frequency is 45 f 5 h". The method is highly selective, and has been used for the determination of perchlorate added to serum and urine samples.


📜 SIMILAR VOLUMES


Indirect atomic absorption spectrometric
✍ P. Martínez-Jimenez; M. Gallego; M. Valcárcel 📂 Article 📅 1987 🏛 Elsevier Science 🌐 English ⚖ 555 KB

Chloride and iodide are injected into a carrier silver nitrate and the precipitates formed are retained on a stainless-steel filter, so that total chloride and iodide can be determined by the decrease in the atomic absorption signal for silver. The silver chloride precipitate is subsequently dissolv

Rapid determination of benzalkonium chlo
✍ J.J. Halvax; G. Wiese; J.A. Arp; J.M.P. Vermeer; W.P. Van Bennekom; A. Bult 📂 Article 📅 1990 🏛 Elsevier Science 🌐 English ⚖ 927 KB

Benzalkonium chloride was assayed by on-line extraction of the benzalkonium ion with picrate to chloroform. The absorbance of picrate was measured. The extractions were performed with a home-made flow injection extraction unit. Calibration curves (1.5-180 x 10(-4)% w/v) were straight lines (r = 0.99

Entrapment of reagents in polymeric mate
✍ L. Lahuerta Zamora; J.V. Garcia Mateo; J. Martinez Calatayud 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 514 KB

Ahstraet A method for entrapment of reagents IS described The expcnmental procedure IS based on the dlsperslon of the reagent (MnOz) mto an unsaturated polyester solution and gnndmg the product to give the required particle size (300-400 pm) The reagent 1s packed mto a bed reactor (15 mm I d I and i

Spectrofluorimetric determination of ber
✍ Tadao Sakai; Noriko Ohno; Yong Soon Chung; Harumitu Nishikawa 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 348 KB

A sensitive and rapid determination of berberine was carried out by flow-injection analysis. Berberine was successfully extracted in the presence of sodium perchlorate. The calibration graph was linear over the range 4 X 10d9-1 X 1O-6 mol dm-". The sample throughput was 42 h-l.