Increasing spatial coverage for high-resolution functional MRI
✍ Scribed by Yanle Hu; Gary H. Glover
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 400 KB
- Volume
- 61
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
For high‐resolution functional MRI (fMRI) studies, one of the major challenges is limited spatial coverage, which results because of the tradeoffs between temporal resolution and covering more k‐space. Given the same temporal resolution, fewer slices can be collected for high‐resolution fMRI. If the number of slices is not large enough to cover all regions of interest, additional scans may become necessary, which increases both the total scan time and the complexity of interpreting data. In this work, we propose a method that combines the undersampled 3D stack‐of‐spirals acquisition method with the UNFOLD technique to significantly increase the spatial coverage for high‐resolution fMRI. Undersampling allows more slices to be fit into a given temporal resolution. The signal‐to‐noise ratio (SNR) drop associated with undersampling can be compensated by the increase in the excited volume in 3D acquisitions. Theoretical analysis shows that although there is a negligible increase in temporal coherence due to spectral filtering in the UNFOLD technique, twice the spatial coverage can be achieved given the same total scan time and similar quality of activation maps, which was confirmed by experiments on normal subjects. Magn Reson Med, 2009. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract For high‐resolution functional MRI (fMRI) studies, signal‐to‐noise ratio (SNR) plays an important role. Any method that results in an improvement in SNR will be able to improve the quality of activation maps. Three‐dimensional (3D) acquisition methods in general can provide higher SNR t
High-resolution MR imaging (312 Frn in plane resolution) and MR spectroscopy (0.36 cm3 nominal voxel) have been performed on human frontal cortex using a 3 in surface coil. Localized proton spectra have been obtained from contiguous 6 x 6 x 10 mm voxels using one-dimensional phase encoding, TR 2000
## Abstract Functional mapping of human brain activation has been accomplished at high spatial __and__ temporal resolution (voxel size 4.9 μl, temporal increment 100 ms). The approach was based on oxygenation‐sensitive long‐echo time FLASH MRI sequences synchronized to multiply repeated cycles of v
## Abstract ## Purpose To combine parallel imaging with 3D single‐shot acquisition (echo volumar imaging, EVI) in order to acquire high temporal resolution volumar functional MRI (fMRI) data. ## Materials and Methods An improved EVI sequence was associated with parallel acquisition and field of