## Abstract Contemporary coronary magnetic resonance angiography techniques suffer from signal‐to‐noise ratio (SNR) constraints. We propose a method to enhance SNR in gradient echo coronary magnetic resonance angiography by using sensitivity encoding (SENSE). While the use of sensitivity encoding t
High temporal resolution functional MRI using parallel echo volumar imaging
✍ Scribed by Cécile Rabrait; Philippe Ciuciu; Alejandro Ribés; Cyril Poupon; Patrick Le Roux; Ghislaine Dehaine-Lambertz; D. Le Bihan; F. Lethimonnier
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 982 KB
- Volume
- 27
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To combine parallel imaging with 3D single‐shot acquisition (echo volumar imaging, EVI) in order to acquire high temporal resolution volumar functional MRI (fMRI) data.
Materials and Methods
An improved EVI sequence was associated with parallel acquisition and field of view reduction in order to acquire a large brain volume in 200 msec. Temporal stability and functional sensitivity were increased through optimization of all imaging parameters and Tikhonov regularization of parallel reconstruction. Two human volunteers were scanned with parallel EVI in a 1.5T whole‐body MR system, while submitted to a slow event‐related auditory paradigm.
Results
Thanks to parallel acquisition, the EVI volumes display a low level of geometric distortions and signal losses. After removal of low‐frequency drifts and physiological artifacts, activations were detected in the temporal lobes of both volunteers and voxelwise hemodynamic response functions (HRF) could be computed. On these HRF different habituation behaviors in response to sentence repetition could be identified.
Conclusion
This work demonstrates the feasibility of high temporal resolution 3D fMRI with parallel EVI. Combined with advanced estimation tools, this acquisition method should prove useful to measure neural activity timing differences or study the nonlinearities and nonstationarities of the BOLD response. J. Magn. Reson. Imaging 2008;27:744–753. © 2008 Wiley‐Liss, Inc.