๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

In vivo microdialysis and reverse phase ion pair liquid chromatography/tandem mass spectrometry for the determination and identification of acetylcholine and related compounds in rat brain

โœ Scribed by Yongxin Zhu; Philip S. H. Wong; Meloney Cregor; James F. Gitzen; Louis A. Coury; Peter T. Kissinger


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
96 KB
Volume
14
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


In vivo microdialysis/liquid chromatogra
โœ Philip S. H. Wong; K. Yoshioka; F. Xie; P. T. Kissinger ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 81 KB

Liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been coupled to in vivo microdialysis for on-line monitoring of melatonin in a freely moving rat for a period of 15 hours. A microdialysis probe was surgically implanted into the jugular vein of the rat, and deionized water was used as th

In vivo microdialysis and liquid chromat
โœ Masucci, John A.; Ortegon, Marta E.; Jones, William J.; Shank, Richard P.; Caldw ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 309 KB ๐Ÿ‘ 1 views

The concentration of a novel anticonvulsant, 2,3 : 4,5-bis-O-(1-methylethylidene)-b-D-fructopyranose sulfamate (topiramate), was determined in the extracellular ร‘uid of rat brain by in vivo microdialysis combined o โ€ -line with liquid chromatography/thermospray mass spectrometry. A microdialysis prob

High performance liquid chromatography m
โœ Mohammed Jemal; Zheng Ouyang; Deborah S. Teitz ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 100 KB ๐Ÿ‘ 2 views

A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T

Accurate mass determinations for the con
โœ A. C. Hogenboom; W. M. A. Niessen; D. Little; U. A. Th. Brinkman ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 113 KB ๐Ÿ‘ 2 views

The identification of polar microcontaminants in surface water is an important issue in environmental analysis. Liquid chromatography/mass spectrometry (LC/MS) is frequently applied for this purpose. However, even in combination with tandem mass spectrometry (MS/MS), unambiguous identification of th

High-performance liquid chromatography t
โœ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 88 KB ๐Ÿ‘ 2 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp