Background and Objectives: Laser tissue repair usually relies on hemoderivate protein solders, based on serum albumin. These solders have intrinsic limitations that impair their widespread use, such as limited tensile strength of repaired tissue, poor solder solubility, and brittleness prior to lase
In vitro and in vivo tissue repair with laser-activated chitosan adhesive
✍ Scribed by A. Lauto; M. Stoodley; H. Marcel; A. Avolio; M. Sarris; G. McKenzie; D.D. Sampson; L.J.R. Foster
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 491 KB
- Volume
- 39
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Background and Objectives
Sutures are currently the gold standard for wound closure but they are still unable to seal tissue and may induce scarring or inflammation. Biocompatible glues, based on polysaccharides such as chitosan, are a possible alternative to conventional wound closure. In this study, the adhesion of laser‐activated chitosan films is investigated in vitro and in vivo. In particular we examine the effect of varying the laser power, as well as adding a natural cross‐linker (genipin) to the adhesive composition.
Study Design/Materials and Methods
Flexible and insoluble strips of chitosan films (surface area ∼34 mm^2^, thickness ∼20 µm) were bonded to sheep intestine using several laser powers (0, 80, 120, and 160 mW) at 808‐nm wavelength. The strength of repaired tissue was tested by a calibrated tensiometer to select the best power. A natural cross‐linker (genipin) was also added to the film and the tissue repair strength compared with the strength of plain films. The adhesive was also bonded in vivo to the sciatic nerve of rats and the thermal damage induced by the laser assessed 4 days post‐operatively.
Results
Chitosan adhesives successfully repaired intestine tissue, attaining a maximum repair strength of 14.7±4.3 kPa (n = 30) at the laser power of 120 mW. The chitosan‐genipin films achieved lower repair strength (9.1±2.9 kPa). The laser caused partial demyelination of axons at the site of operation, but the myelinated axons retained a normal morphology proximally and distally.
Conclusions
The chitosan adhesive effectively bonded to tissue causing only localized thermal damage in vivo, when the appropriate laser parameters were selected. Lasers Surg. Med. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Background and objective: Severed tibial nerves in rats were repaired using a novel technique, utilizing a semiconductor diode-laser-activated protein solder applied longitudinally across the join. welding was produced by selective laser denaturation of solid solder bands containing the dye indo
A flexible approach is described to acquire, store, retrieve, and manipulate the large volume of data provided by a rapid-scanning spectrophotometer designed for biological preparations. Data can be displayed in spectral and kinetic formats. This spectrophotometer provides a means to simultaneously
## Abstract There is a clinical requirement for a local hemostat that arrests bleeding from both suture holes and cross‐sectional surfaces of parenchymatous organs. A novel tissue‐adhesive hydrogel was prepared that contains a cross‐linkable polymeric micelle consisting of poly(ethylene glycol)‐pol
## Abstract ## Background and Objectives Tissue damage during endoscopic treatment of urethral and ureteral strictures may result in stricture recurrence. The Erbium:YAG laser ablates soft tissues with minimal peripheral damage and may be a promising alternative to cold knife and Holmium:YAG laser