𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Chitosan adhesive for laser tissue repair: In vitro characterization

✍ Scribed by Antonio Lauto; J. Hook; M. Doran; F. Camacho; L.A. Poole-Warren; A. Avolio; L.J.R. Foster


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
172 KB
Volume
36
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Background and Objectives: Laser tissue repair usually relies on hemoderivate protein solders, based on serum albumin. These solders have intrinsic limitations that impair their widespread use, such as limited tensile strength of repaired tissue, poor solder solubility, and brittleness prior to laser denaturation. Furthermore, the required activation temperature of albumin solders (between 65 and 708C) can induce significant thermal damage to tissue. In this study, we report on the design of a new polysaccharide adhesive for tissue repair that overcomes some of the shortcomings of traditional solders. Study Design/Materials and Methods: Flexible and insoluble strips of chitosan adhesive (elastic modulus $6.8 Mpa, surface area $34 mm 2 , thickness $20 mm) were bonded onto rectangular sections of sheep intestine using a diode laser (continuous mode, 120 AE 10 mW, l ¼ 808 nm) through a multimode optical fiber with an irradiance of $15 W/cm 2 . The adhesive was based on chitosan and also included indocyanin green dye (IG). The temperature between tissue and adhesive was measured using a small thermocouple (diameter $0.25 mm) during laser irradiation. The repaired tissue was tested for tensile strength by a calibrated tensiometer. Murine fibroblasts were cultured in extracted media from chitosan adhesive to assess cytotoxicity via cell growth inhibition in a 48 hours period. Results: Chitosan adhesive successfully repaired intestine tissue, achieving a tensile strength of 14.7 AE 4.7 kPa (mean AE SD, n ¼ 30) at a temperature of 60-658C. Media extracted from chitosan adhesive showed negligible toxicity to fibroblast cells under the culture conditions examined here. Conclusion: A novel chitosan-based adhesive has been developed, which is insoluble, flexible, and adheres firmly to tissue upon infrared laser activation.


📜 SIMILAR VOLUMES


In vitro and in vivo tissue repair with
✍ A. Lauto; M. Stoodley; H. Marcel; A. Avolio; M. Sarris; G. McKenzie; D.D. Sampso 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 491 KB

## Abstract ## Background and Objectives Sutures are currently the gold standard for wound closure but they are still unable to seal tissue and may induce scarring or inflammation. Biocompatible glues, based on polysaccharides such as chitosan, are a possible alternative to conventional wound clos

In vitro biocompatibility of fluorcanasi
✍ S. Bandyopadhyay-Ghosh; I.M. Reaney; I.M. Brook; K. Hurrell-Gillingham; A. Johns 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 590 KB

## Abstract Fluorcanasite glass‐ceramics were produced by controlled two stage heat‐treatment of as‐cast glasses. These glasses were modified from stoichiometric fluorcanasite composition by either adding P~2~O~5~ or altering the molar ratios of Na~2~O and CaO. Commercial bioactive 45S5 Bioglass® w

Antibiotic-loaded chitosan film for infe
✍ J. Keaton Smith; Joel D. Bumgardner; Harry S. Courtney; Mark S. Smeltzer; Warren 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 690 KB

## Abstract The growing infection rate by methicillin‐resistant __Staphylococcus aureus__, especially with bone fracture fixation implants, is a major concern in extremity musculoskeletal wound treatment. This preliminary investigation evaluates the ability of chitosan film to be loaded with daptom

In vitro multipotentiality and character
✍ Sang Yang Lee; Masahiko Miwa; Yoshitada Sakai; Ryosuke Kuroda; Tomoyuki Matsumot 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 397 KB

## Abstract Mesenchymal progenitor cells (MPCs) are a very attractive tool in the context of repair and regeneration of musculoskeletal tissue damaged by trauma. The most common source of MPCs to date has been the bone marrow, but aspirating bone marrow from the patient is an invasive procedure. In

Chitosan scaffolds for in vitro buffalo
✍ Wah W. Thein-Han; Yindee Kitiyanant 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 669 KB

## Abstract Three‐dimensional (3D) porous chitosan scaffolds are attractive candidates for tissue engineering applications. Chitosan scaffolds of 70, 88, and 95% degree of deacetylation (% DD) with the same molecular weight were developed and their properties with buffalo embryonic stem‐like (ES‐li