## Abstract The clinical use of plasma‐sprayed hydroxyapatite (HA) coatings on metal implants has been widely adopted because the HA coating can achieve the firmly and directly biological fixation with the surrounding bone tissue. However, the long‐term mechanical properties of HA coatings has been
In vitro and in vivo biological responses of plasma-sprayed hydroxyapatite coatings with posthydrothermal treatment
✍ Scribed by C. Y. Yang; T. M. Lee; C. W. Yang; L. R. Chen; M. C. Wu; T. S. Lui
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 383 KB
- Volume
- 83A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
This study was undertaken to evaluate the effect of post‐hydrothermal treatment on the biological responses of the plasma‐sprayed hydroxyapatite (HA)‐coated Ti‐6Al‐4V implant system both in vitro and in vivo. After hydrothermal treatment, the HA coating (HAC) shows the high mechanical strength and indices‐of‐crystallinity, denser microstructure, lower concentrations of amorphous and impurity phases, when compared with the as‐sprayed HAC. The in vitro cell‐culture studies, using UMR106 osteoblast‐like cell, demonstrated no signifiacnt cell growth on both surface of as‐sprayed and hydrothermal‐treated HACs during 10‐day culture. The in vivo studies, using the transcortical implant model in the femora of goats, evaluated the histological responses of two coatings. After 6 week of implantation, using backscattered electron images, no substantial histological variations in the extents of new bone apposition and new bone healing between the two HACs were observed. However, the as‐sprayed HAC, owing to the dissolution induced the granular particles dissociated from the HAC, showed the statically lower extent of new bone apposition than hydrothermal‐treated HAC at 12 weeks. The results suggest that hydrothermal treatment could be used to improve the mechanical strength, crystallinity, and phase composition of HAC, which are important factors of long‐term fixation and stability of implant. Besides, the treated HAC could also achieve the initial fixation of implant in clinical use. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
📜 SIMILAR VOLUMES
This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurityphases, and indi
The purpose of this study was to evaluate the effect of atmo-sphere, tricalcium phosphate (TCP) and tetracalcium phossphere on the phase transformation in hydroxyapatite (HA) phate (TTCP) were more stable than HA, so heat treatcoatings during heat treatment by varying the atmosphere ment could not c
The loss of calcium from plasma-sprayed calcium phosphate ceramics (CPCs) on bioinert metal substrate (Ti-6Al-4V) immersed in cell culture medium with or without human osteoblast culture was measured. The ceramics were a CPC and a duplex system composed of a CPC layer on an alumina coating. The diss
## Abstract The geometric design and chemical compositions of an implant surface may have an important part in affecting early implant stabilization and influencing tissue healing. In this study, __in vivo__ behavior and mechanical stability in implants of three surface designs, which were smooth s