𝔖 Bobbio Scriptorium
✦   LIBER   ✦

In-plane velocity encoding with coherent steady-state imaging

✍ Scribed by John Grinstead; Shantanu Sinha


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
448 KB
Volume
54
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Standard phase‐contrast flow quantification (PC‐FQ) using radiofrequency (RF) spoiled steady‐state (SS) incoherent gradient‐echo sequences have a relatively low signal‐to‐noise ratio (SNR). Unspoiled SS coherent (SSC) gradient‐echo sequences have a higher intrinsic SNR and are T~2~/T~1~ weighted so that blood has a relatively large signal compared to other tissues. An SSC sequence that was modified to allow in‐plane velocity encoding is presented. Velocity encoding was achieved by inverting the readout gradients. This offers the benefit that there is no resultant increase in repetition time (TR), which avoids increased sensitivity to off‐resonance artifacts when conventional velocity‐encoding methods using separate velocity‐encoding gradients are extended to SSC sequences. The results of standard PC‐FQ and the new method from in vitro experiments of constant and sinusoidal flow, and in vivo imaging of the carotid artery were compared. Vector field maps and paths obtained from particle‐tracking calculations based on the velocity‐encoded images were used to visualize the velocity data. The technique has the potential to increase the precision of PC‐FQ measurements. Magn Reson Med 54:138–145, 2005. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Improved aortic pulse wave velocity asse
✍ Jos J.M. Westenberg; Albert de Roos; Heynric B. Grotenhuis; Paul Steendijk; Denn 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 367 KB

Purpose: To evaluate the accuracy and reproducibility of aortic pulse wave velocity (PWV) assessment by in-plane velocity-encoded magnetic resonance imaging (MRI). Materials and Methods: In 14 patients selected for cardiac catheterization on suspicion of coronary artery disease and 15 healthy volun

Coherence-induced artifacts in large-fli
✍ Branimir Vasilic; Hee Kwon Song; Felix W. Wehrli 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 408 KB

## Abstract High‐resolution imaging of trabecular bone aimed at analyzing the bone's microarchitecture is preferably performed with spin‐echo‐type pulse sequences. Unlike gradient echoes, spin‐echoes are immune to artifactual broadening of trabeculae caused by local static field gradients near the

Characterization and reduction of satura
✍ Jamal J. Derakhshan; Mark A. Griswold; Sherif G. Nour; Jeffrey L. Sunshine; Jeff 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 460 KB

## Abstract Hypointense band artifacts occur at intersections of nonparallel imaging planes in rapidly acquired MR images; quantitative or numerical analysis of these bands and strategies to mitigate their appearance have largely gone unexplored. The magnetization evolution in the different regions

Flow pattern analysis in the abdominal a
✍ Gerhard H. Mostbeck; Matthias C. Dulce; Gary R. Caputo; Evelyn Proctor; Charles 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 952 KB

## Abstract The sites of deposition of atherosclerotic plaque on the aortic wall are considered to be influenced by secondary and retrograde flow patterns that cause regions of altered shear stress. To detect secondary flow patterns and areas of retrograde flow in the abdominal aorta, velocity‐enco

Detecting microcirculatory changes in bl
✍ Rohan Dharmakumar; Xiuling Qi; Juimiin Hong; Graham A. Wright 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 424 KB

## Abstract Recently, it has been demonstrated that oxygen‐weighted images of whole blood can be obtained with steady‐state methods. In this article, based on computational and experimental models, we investigate the potential for employing this technique to monitor oxygen changes in microcirculati