𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Flow pattern analysis in the abdominal aorta with velocity-encoded cine MR imaging

✍ Scribed by Gerhard H. Mostbeck; Matthias C. Dulce; Gary R. Caputo; Evelyn Proctor; Charles B. Higgins


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
952 KB
Volume
3
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The sites of deposition of atherosclerotic plaque on the aortic wall are considered to be influenced by secondary and retrograde flow patterns that cause regions of altered shear stress. To detect secondary flow patterns and areas of retrograde flow in the abdominal aorta, velocity‐encoded cine (VEC) magnetic resonance (MR) imaging was performed at five different levels of the abdominal aorta in nine healthy volunteers. Net retrograde flow (expressed as a percentage of antegrade flow) increased from proximal to distal levels and was maximal (13.8% ± 11.8) just distal to the origin of the renal arteries. An increase in the duration of retrograde flow over the cardiac cycle was observed from proximal to distal levels. Whereas retrograde flow was present at end systole and early diastole in each volunteer at every level, the duration and amount of retrograde flow during diastole showed high interindividual variation. Such differences suggest the possibility of variable vascular geometric risk factors in the population for the development of atherosclerotic plaque. The location of retrograde flow in the abdominal aorta demonstrated in vivo with VEC MR imaging was close to that obtained with in vitro flow visualization studies in models of the abdominal aorta.


📜 SIMILAR VOLUMES


Myocardial blood flow in patients with d
✍ Norbert Watzinger; Gunnar K. Lund; Maythem Saeed; Gautham P. Reddy; Philip A. Ar 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 246 KB

## Abstract ## Purpose To quantify global myocardial perfusion using magnetic resonance imaging (MRI) in patients with heart failure due to idiopathic dilated cardiomyopathy (IDC) and to compare myocardial perfusion and microvascular reactivity with healthy subjects. ## Materials and Methods A t

Velocity and flow quantitation in the su
✍ John E. Jordan; Norbert J. Pelc; Dieter R. Enzmann 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 568 KB

## Abstract Normal blood flow and velocity in the superior sagittal sinus were measured in 30 patients. A fast two‐dimensional ungated phase‐contrast (PC) pulse sequence was compared with a peripherally gated cine PC technique for velocity and flow quantitation. The same imaging parameters were use

Flow patterns in the dilated ischemic le
✍ Raad H. Mohiaddin 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 850 KB

## Abstract Magnetic reaonance velocity vector mapping was used to study flow patterns in dilated and healthy left ventricles. Eleven patients (age mean ± SD, 67 ± 12 yeare) with dilated left ventricle resulting from coronary artery diclease and 10 healthy volunteers (age 50 ± 9) were studied. Cine

Accelerated phase-contrast MR imaging: C
✍ Andreas Stadlbauer; Wilma van der Riet; Sebastian Globits; Gerard Crelier; Erich 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 457 KB

## Abstract ## Purpose To evaluate differences in velocity and flow measurements in the aorta between accelerated phase‐contrast (PC) magnetic resonance imaging (MRI) using SENSE and k‐t BLAST and in peak velocity to Doppler ultrasound. ## Materials and Methods Two‐dimensional PC‐MRI perpendicul

Correlation of cine MR velocity measurem
✍ Wayne L. Davis; Patrick A. Turski; Kristina G. Gorbatenko; David Weber 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 949 KB

## Abstract The velocity‐phase relationship intrinsic to phase‐contrast magnetic resonance (MR) angiography permits the quantitative and qualitative assessment of blood flow. The ability to measure velocity and vessel cross‐sectional area allows noninvasive assessment of volume flow rate (VFR) in t