𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Homogeneous sample preparation for automated high throughput analysis with matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry

✍ Scribed by Patrik Önnerfjord; Simon Ekström; Jonas Bergquist; Johan Nilsson; Thomas Laurell; György Marko-Varga


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
552 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture onto a pre-deposited highly diluted matrix spot. The pre-deposited crystals act as seeds for the new sample containing crystals which become much smaller in size and more evenly distributed than with conventional methods. This 'seed-layer' method was developed, optimised and compared with the dried-droplet method using peptides and proteins in the 1000-20 000 Da range. The seed-layer method increases the surface homogeneity, spot to spot reproducibility and sample washability as compared with the commonly used dried-droplet method. This methodology is applicable to a-cyanohydroxycinnamic acid, sinapinic acid and ferulic acid, which all form homogeneous crystal surfaces. Within-spot variation and between-spot variation was investigated using statistics at a 95% confidence level (n = 36). The statistical values were generated from more than 5000 data points collected from 500 spectra. More than 90% of the sample locations results in high intensity spectra with relatively low standard deviations (RSDs). Typically obtained data showed an RSD of 19-35% within a sample spot as well as in-between spots for proteins, and an RSD of 50% for peptides. Linear calibration curves were obtained within one order of magnitude using internal calibration with a point-RSD of 3% (n = 10). The sample homogeneity allows mass spectra (average of 16 laser shots) to be obtained on each individual sample within 15 sec, whereby a 100 spot target plate can be run in 25 min. High density target plates using the seed-layer method were prepared by spotting %100 picoliter droplets onto the target, resulting in sample spots 500 mm in diameter using a flow-through piezo-electric microdispenser. By using this automated sample preparation step lower standard deviations are obtained in comparison to manually prepared samples.


📜 SIMILAR VOLUMES


Sample preparation for high throughput a
✍ Derek A. Lake; Murray V. Johnson; Charles N. McEwen; Barbara S. Larsen 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 79 KB 👁 2 views

An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed

Simplified sample preparation for the an
✍ G. John Langley; Julie M Herniman; Nichola L Davies; Tom Brown 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 106 KB 👁 2 views

Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the analyses of oligonucleotides has generally been carried out using negative ionisation conditions, usually following ammonium ion-exchange chromatography and the addition of ammonium buffers to the MALD

How feasible is matrix-assisted laser de
✍ Meike Reinhold; Robert J. Meier; Chris G. de Koster 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 63 KB 👁 2 views

Ab initio quantum calculations were applied to obtain binding energies for sodium cation-oligomer complexes comprising either methanol, ethylene glycol oligomers or n-alkanes. In addition, it was experimentally shown using sodium cations that ethylene glycol oligomers could not be detected when cons

Electrospray sample preparation for impr
✍ Russell R. Hensel; Richard C. King; Kevin G. Owens 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 185 KB 👁 2 views

The goal of this work is the development of a rapid and objective matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) method for the quantitation of peptides and proteins in human plasma suitable for use in the Good Laboratory Practices (GLP) environment, where

Sample Preparation Optimization for the
✍ Camafeita, Emilio; Alfonso, Patricia; Acevedo, Boris; Méndez, Enrique 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 318 KB 👁 2 views

Analysis by matrix-assisted laser desorption/ionization time-of-Ñight mass spectrometry (MALDI/TOF-MS) of wheat gliadin extracts from distinct types of wheat varieties displays a similar characteristic gliadin mass pattern within the 30-40 kDa range. Direct observation of this pattern in food sample