𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Electrospray sample preparation for improved quantitation in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

✍ Scribed by Russell R. Hensel; Richard C. King; Kevin G. Owens


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
185 KB
Volume
11
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


The goal of this work is the development of a rapid and objective matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) method for the quantitation of peptides and proteins in human plasma suitable for use in the Good Laboratory Practices (GLP) environment, where the analytical method, validation and pharmacokinetic parameters derived from concentration data will be scrutinized by global regulatory agencies. Electrospray deposition has traditionally been used to prepare thin, uniform samples for a number of techniques, including Cf-252 plasma desorption and secondary ion mass spectrometry.

Here the electrospray process of sample application is used to reduce the segregation of analyte from matrix during the sample drying step. The small droplets formed during the electrospray process are found to significantly improve the homogeneity of the sample surface prepared. Experiments comparing the traditional air dried and electrosprayed methods of sample preparation show that the increase in sample homogeneity from electrosprayed samples deccreases both the within-sample spot and between-sample spot variability, resulting in a decrease in percent coefficient of variation (%CV) for the recorded MALDI mass spectra. The increase in sample homogeneity permits a more objective use of MALDI-TOFMS as a quantitative analytical method and has led to the development of an assay for the determination of desamino-[8-D-arginine] vasopressin (DDAVP) using arginine vasopressin (AVP) as internal standard in human plasma. The range of quantitation observed (2.0-10 g/mL) is of limited value for bioanalytical application; however, the analysis of neat standards shows lower quantitation limits are easily achieved.


πŸ“œ SIMILAR VOLUMES


Sample preparation for high throughput a
✍ Derek A. Lake; Murray V. Johnson; Charles N. McEwen; Barbara S. Larsen πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 79 KB πŸ‘ 2 views

An automated sample preparation for high throughput accurate mass determinations by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been developed. Sample preparation was performed with an automated workstation and automated mass analyses were performed

Quantitative analysis of antibiotics by
✍ Yong-Chien Ling; Lihnian Lin; Yi-Ting Chen πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 242 KB πŸ‘ 2 views

Comparative studies of the matrix-assisted laser desorption/ionization (MALDI) of 30 antibiotics were made using a-cyano-4-hydroxycinnamic acid (HCCA), 2,5-dihydroxybenzoic acid (DHB), 5,10,15,20tetrakis(4-hydroxyphenyl)-21H,23H-porphyrin and meso-tetra(N-methyl-4-pyridyl)porphyrin matrices. Most an

Ionization mechanism of oligonucleotides
✍ Yufei Kong; Yifei Zhu; Jing-Yuan Zhang πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 171 KB πŸ‘ 1 views

The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the ba

Time-of-flight effects in matrix-assiste
✍ T.-P. E. Sze; T.-W. Dominic Chan πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 137 KB πŸ‘ 1 views

The time-of-flight effect in Fourier transform mass spectrometry (FTMS) with an external ion source was quantified. The time-of-flight profiles of ions of different masses were measured by stepping the time interval between the ionization pulse and the gating of the trapping voltage (T gate ). The o

Sample Preparation Optimization for the
✍ Camafeita, Emilio; Alfonso, Patricia; Acevedo, Boris; MΓ©ndez, Enrique πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 318 KB πŸ‘ 1 views

Analysis by matrix-assisted laser desorption/ionization time-of-Γ‘ight mass spectrometry (MALDI/TOF-MS) of wheat gliadin extracts from distinct types of wheat varieties displays a similar characteristic gliadin mass pattern within the 30-40 kDa range. Direct observation of this pattern in food sample