𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Highly sensitive determination of haloperidol in human serum by capillary gas chromatography using a surface ionization detector

✍ Scribed by Nagai, Yumi ;Arimoto, Hiromi ;Fujii, Toshihiro


Publisher
John Wiley and Sons
Year
1990
Tongue
English
Weight
270 KB
Volume
13
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A method has been developed for highly sensitive determination of haloperidol in human serum involving a simple extraction procedure followed by gas chromatographic separation. Target components were separated from the extracting solvents with a Van den Berg type solventless sample injector before introduction Into a DB‐1 capillary separation column. A surface ionization detector (SID), which has highly selective sensitivity for Substituted amines, was employed for quantitation using bromperidol as an internal standard. Chloroform proved to be the best extracting solvent, yielding a quantitative detection limit of 5 ng/ml (S/N = 2). Comparison of the response to target compounds obtained by the SID, FTD (flame thermionic detector), and FID (flame ionization detector) showed the SID to be superior.


πŸ“œ SIMILAR VOLUMES


Determination of lidocaine in human seru
✍ Arimoto, Hiromi ;Shiomi, Koichi ;Fujii, Toshihiro πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 311 KB πŸ‘ 1 views

## Abstract A novel analytical method has been developed for the determination of lidocaine (2‐(diethylamino)‐__N__‐(2,6‐dimethyl)phenylacetamide) in human serum. After solvent extraction from serum the extract was analyzed by gas chromatography employing a __van den Berg__ type solventless injecto

Determination of curcumol in rat plasma
✍ Xiao Zhao; Yu-Ling Liu πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 217 KB πŸ‘ 2 views

## Abstract A simple and sensitive capillary gas chromatography with a hydrogen flame ionization detector (GC‐FID) method was developed for the determination of curcumol in rat plasma. From a variety of compounds and solvents tested, buagafuran was selected as the internal standard (IS) and acetoni

Determination of 17Ξ²-estradiol in bovine
✍ Giancarlo Biancotto; Roberto Angeletti; Pietro Traldi; Massimiliano Silvestri; M πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 141 KB

## Abstract A novel approach to the determination of 17β‐estradiol in bovine plasma is presented. The observed enhanced sensitivity is gained by the application of tandem mass spectrometry (MS) fragmentation to a stable, well characterized negative ion produced by chemical ionization (methane as re