The infrared spectrum of monoiodoacetylene has been recorded in certain selected wavenumber regions between 200 and \(3500 \mathrm{~cm}^{-1}\) with a Fourier transform spectrometer at resolutions varying from 0.0025 to \(0.0046 \mathrm{~cm}^{-1}\). All five fundamental bands of the \(\mathrm{HCCI}\)
High-Resolution Infrared Study of the Fundamental Bands of Deuteroiodoacetylene
β Scribed by H. Sarkkinen; A.-M. Tolonen; S. Alanko
- Publisher
- Elsevier Science
- Year
- 1997
- Tongue
- English
- Weight
- 209 KB
- Volume
- 185
- Category
- Article
- ISSN
- 0022-2852
No coin nor oath required. For personal study only.
β¦ Synopsis
The high-resolution infrared spectrum of deuterated iodoacetylene has been measured in the region 200-2700 cm 01 . In addition to all five fundamentals, the bands 2n 0 4 and 2n 0 5 have been identified. The measurements were carried out by using a Fourier transform spectrometer at room temperature with instrumental resolution of about 0.0020 cm 01 . The ground state rotational constants B 0 Γ 0.0970742961(72) cm 01 , D 0 Γ 1.38482(20) 1 10 08 cm 01 , and H 0 Γ 01.47(10) 1 10 015 cm 01 have been determined by combining 462 ground state combination differences from the same bands mentioned above with accurate MW data from the literature. In addition, the molecular constants for all the fundamental levels have been obtained.
π SIMILAR VOLUMES
The hot band structure of the high-resolution Fourier transform spectra of monoiodoacetylene measured in the region of the bending fundamental n 1 4 (600-655 cm 01 ) with a resolution of 0.0020 cm 01 has been studied in detail. In addition, three spectra n 4 / n 5 0 n 4 (180-320 cm 01 ), 2n 0 4 (122
The high-resolution (2.3 Γ 10 -3 cm -1 ) Fourier transform infrared spectrum of PHD 2 was recorded for the first time and analyzed in the region of the three lowest bands belonging to the three bending fundamentals. Between 1100 and 1800 transitions were assigned to each of the Ξ½ 3 , Ξ½ 4 , and Ξ½ 6 b
The high-resolution infrared spectrum of allene has been observed in the 280-380 cm -1 region at a nominal resolution of 0.00125 cm -1 using the IR beamline at the MAX-I electron storage ring in Lund. The spectrum shows the bending fundamental of the Ξ½ 11 band from which spectroscopic constants for
Using high-resolution Fourier transform spectra, a thorough analysis of the 14 c-type, 17 a-type, and 18 a-type bands of both 11 B 2 H 6 and 10 B 11 BH 6 has been carried in the 10.3-, 6.2-, and 8.5-m spectral regions, respectively. From this analysis a large set of precise ground state combination
The lowest fundamental band \(\nu_{13}\) of triacetylene \(\left(\mathrm{HC}_{6} \mathrm{H}\right)\) was measured in high resolution using a Fourier transform IR spectrometer in the range from 27 to \(227 \mathrm{~cm}^{-1}\). The resolution achieved was about \(0.0018 \mathrm{~cm}^{-1}\). The rotati