High Resolution Inductively Coupled Plasma Mass Spectra with a Quadrupole Mass Filter
β Scribed by Ji-Feng Ying; D. J. Douglas
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 388 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
An inductively coupled plasma mass spectrometer (ICP-MS) system is described in which the quadrupole mass filter can be operated conventionally or in the 'second' stability region (with Mathieu parameters q=7.547, a=0.0295). With operation in the second region a resolution at half-height (Rw) of up to 9000 can be achieved at ndz = 55. At R, = 5000, a resolution sufficient to separate atomic ions from common molecular ion interferences (such "Fe' and 4oAr160+), the sensitivity is cu. lo6 ions s-' per pg mL-' of element in solution. This sensitivity is comparable to that of current sector ICP-MS systems operated at the same resolution. When the quadrupole is operated in the fist stability region, the sensitivity is cu. 108 ions s-' per pg mL-' of element in solution. The continuum background is high, ca lo00 s-', but no attempts have yet been made to reduce this. The results suggest that with continued development, a high resolution quadrupole ICP-MS system will be possible.
π SIMILAR VOLUMES
The coupling of a Rydberg electron capture ion source with a Nermag R10-10H quadrupole mass filter is described. Details are given of the addition to this instrument of a creation cell for atoms excited in Rydberg states. Within the Nermag ion source, such atoms allow attachment of electrons of well
The quantitative determination of nucleotides from DNA modiΓed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui
The analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) for the inorganic analysis of alcoholic beverages was evaluated using double-focusing sector "eld ICP-MS (ICP-SMS). No sample pre-treatment other than acidi"cation and dilution was carried out. Though aspiration of e
Thermospray (TSP) sample introduction methods have been found to selectively deposit Cr(III) in the presence of Cr(VI) and thus provide a direct, nonchromatographic speciation capability for these chromium oxidation states. Previous results have shown that the sensitivity for Cr(III) could be reduce
Inductively coupled plasma mass spectrometry (ICP-MS) for elemental analysis has been dominated since its introduction by instruments with quadrupole Γlters for mass separation. Although considerably impeded by isobaric ion interferences, ICP-MS with quadrupoles has nevertheless matured to become th