𝔖 Bobbio Scriptorium
✦   LIBER   ✦

GLC determination of α- and β-tribenosides in human plasma

✍ Scribed by Antoine Sioufi; Françoise Pommier


Book ID
102406330
Publisher
John Wiley and Sons
Year
1980
Tongue
English
Weight
315 KB
Volume
69
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.

✦ Synopsis


The determination of a-tribenoside at concentrations down to 10 ng/ml and P-tribenoside at concentrations down to 5 ng/ml in human plasma is described. After addition of an internal standard, aand P-tribenosides are extracted at basic pH into benzene. Both compounds are derivatized with N-heptafluorobutyrylimidazole. The derivatives are determined by GLC using a 63Ni-electron-capture detector.

Keyphraees 0 Tribenoside-GLC determination of a-and P-anomers, human plasma 0 Anti-inflammatory agents--tribenoside, GLC determination of a-and 8-anomers, human plasma Antiphlebotic agents-tribenoside, GLC determination of a-and P-anomers, human plasma


📜 SIMILAR VOLUMES


GLC determination of warfarin in human p
✍ S. Hanna; M. Rosen; P. Eisenberger; L. Rasero; L. Lachman 📂 Article 📅 1978 🏛 John Wiley and Sons 🌐 English ⚖ 314 KB 👁 1 views
GLC determination of phenylbutazone in h
✍ Antoine Sioufi; Francoise Caudal; Francoise Marfil 📂 Article 📅 1978 🏛 John Wiley and Sons 🌐 English ⚖ 334 KB

A GLC method for phenylbutazone at concentrations down to 10 ng/ml in human plasma is described. After addition of an internal standard, phenylbutazone is extracted at pH 5 into benzene. The dry extract is dissolved in benzene, and phenylbutazone is determined by GLC using a 63Ni-electron-capture de