Functional NMR imaging using fast spin echo at 1.5 T

✍ Scribed by R. Todd Constable; Richard P. Kennan; Aina Puce; Gregory McCarthy; John C. Gore


Publisher
John Wiley and Sons
Year
1994
Tongue
English
Weight
673 KB
Volume
31
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Functional NMR imaging of the brains response to a simple visual task has been performed using a fast spin echo (FSE) imaging sequence at 1.5 T. The FSE method refocuses dephasing effects induced by large‐scale susceptibility variations, and permits imaging in regions where macroscopic field gradients produce artifacts in gradient echo sequences. At 1.5 T, gradient echo (GRE) sequences are sensitive to the effects of brain activation, but relatively large effects may arise from large vessels and veins, and these may dominate the effects produced by smaller capillaries. Spin echo (SE) sequences with short echo times are relatively immune to large vessel effects and emphasize the susceptibility induced losses from small capillaries, but the imaging time for these sequences is prohibitive for most functional brain studies. We demonstrate that multislice functional brain imaging may be performed in reasonable imaging times at 1.5 T using an FSE imaging sequence. The FSE sequence with short echo spacing but long effective TE is sensitive to susceptibility induced effects at the capillary level. It is not sensitive to larger scale in homogeneities such as those found in veins and can be used in regions near tissuelair boundaries. Results are shown comparing conventional GRE and FSE images in activation of the visual cortex and these are supported by theoretical calculations and phantom experiments.


📜 SIMILAR VOLUMES


Imaging of the wrist at 1.5 tesla using
✍ Kathryn J. Stevens; Charles G. Wallace; Weitian Chen; Jarrett K. Rosenberg; Garr 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 450 KB

## Abstract ## Purpose: To compare three‐dimensional fast spin echo Cube (3D‐FSE‐Cube) with conventional 2D‐FSE in MR imaging of the wrist. ## Materials and Methods: The wrists of 10 volunteers were imaged in a 1.5 Tesla MRI scanner using an eight‐channel wrist coil. The 3D‐FSE‐Cube images were

Myocardial T mapping free of distortion
✍ Uwe Heinrichs; Jane F. Utting; Tobias Frauenrath; Fabian Hezel; Gabriele A. Krom 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 762 KB

## Abstract This study demonstrates the feasibility of applying free‐breathing, cardiac‐gated, susceptibility‐weighted fast spin‐echo imaging together with black blood preparation and navigator‐gated respiratory motion compensation for anatomically accurate __T__ mapping of the heart. First, __T__

Fast 3D functional magnetic resonance im
✍ Yihong Yang; Gary H. Glover; Peter van Gelderen; Venkata S. Mattay; Attanagoda K 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 795 KB

## Abstract A new method to perform rapid 3D fMRI in human brain is introduced and evaluated in normal subjects, on a standard clinical scanner at 1.5 Tesla. The method combines a highly stable gradient echo technique with a spiral scan method, to detect brain activation related changes in blood ox

Sources of intensity nonuniformity in sp
✍ Andrew Simmons; Paul S. Tofts; Gareth J. Barker; Simon R. Arridge 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 747 KB

## Abstract This manuscript describes a number of sources of nonuniformity for spin echo images at 1.5 T. Both coil tuning and crosstalk can have significant effects on image nonuniformity. For short repetition times, nonuniformity increases with decreasing __TR__, possibly due to gradient eddy cur

Snapshot imaging at 0.5 t using echo-pla
✍ R. J. Ordidge; A. Howseman; R. Coxon; R. Turner; B. Chapman; P. Glover; M. Stehl 📂 Article 📅 1989 🏛 John Wiley and Sons 🌐 English ⚖ 753 KB

Echo-planar imaging using a magnetic field strength of 0.5 T has resulted in an improvement in image quality compared with recent images published at 0.1 T. The sensitivity ofthe technique to main magnetic field inhomogeneity and transient eddy currents has necessitated innovations in gradient and r

Automated shimming at 1.5 t using echo-p
✍ Timothy G. Reese; Timothy L. Davis; Robert M. Weisskoff 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 920 KB

## Abstract Using echo‐planar imaging, we developed an automated image‐based procedure to shim the static (B~0~) field. Our method uses the rapid acquisition capability of echo‐planar Imaging to collect the required frequency data rapidly, rendering the shim data acquisition time negligible in comp