𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Functional colonography of Min mice using dark lumen dynamic contrast-enhanced MRI

✍ Scribed by C. Chad Quarles; Martin Lepage; D. Lee Gorden; Barbara Fingleton; Thomas E. Yankeelov; Ronald R. Price; Lynn M. Matrisian; John C. Gore; J. Oliver McIntyre


Book ID
102534868
Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
437 KB
Volume
60
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Dark lumen MRI colonography detects colonic polyps by minimization of the intestinal lumen signal intensity. Here we validate the use of perfluorinated oil as an intestinal‐filling agent for dark lumen MRI studies in mice, enabling the physiological characterization of colonic polyps by dynamic contrast‐enhanced MRI. In control and Min (multiple intestinal neoplasia) mice with and without pretreatment with oral dextran sodium sulfate (DSS), polyps as small as 0.94 mm diameter were consistently identified using standard 2D gradient echo imaging (voxel size, 0.23 × 0.16 × 0.5 mm). In serial studies, polyp growth rates were heterogeneous with an average ≈5% increase in polyp volume per day. In DSS‐treated control mice the colon wall contrast agent extravasation rate constant, K^trans^, and extravascular extracellular space volume fraction, v~e~, values were measured for the first time and found to be 0.10 ± 0.03 min^−1^ and 0.23 ± 0.09, respectively. In DSS‐treated Min mice, polyp K^trans^ values (0.09 ± 0.04 min^−1^) were similar to those in the colon wall but the v~e~ values were substantially lower (0.16 ± 0.03), suggesting increased cellular density. The functional dark‐lumen colonography approach described herein provides new opportunities for the noninvasive assessment of gastrointestinal disease pathology and treatment response in mouse models. Magn Reson Med 60:718–726, 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Use of cardiac output to improve measure
✍ Jeff L. Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 488 KB

## Abstract ## Purpose To validate a new method for converting MR arterial signal intensity versus time curves to arterial input functions (AIFs). ## Materials and Methods The method constrains AIF with patient's cardiac output (Q). Monte Carlo simulations of MR renography and tumor perfusion pr

Assessment of protamine-induced thrombos
✍ Min-Ying Su; Michael K. Samoszuk; Jun Wang; Orhan Nalcioglu 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 366 KB

## Abstract Since the role of angiogenesis in cancer development has been recognized, the study of anti‐angiogenic or anti‐vascular therapeutic agents has become increasingly important for cancer treatment. Selective thrombosis is one approach towards this goal. Since many types of carcinoma accumu

Quantitation of differential renal blood
✍ Michael Pedersen; Yimin Shi; Peter Anderson; Hans Stødkilde-Jørgensen; Jens Chri 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 338 KB

## Abstract A first‐pass upslope approach was used to estimate differential renal blood flow (DRBF) and a Patlak‐Rutland approach was used to estimate differential renal function (DRF) using Gd‐DTPA‐BMA‐enhanced MRI. DRBF and DRF were estimated in rat kidneys under three different experimental cond

Measurement of single kidney function us
✍ David L. Buckley; Ala'a E. Shurrab; Ching M. Cheung; Andrew P. Jones; Hari Mamto 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 461 KB

## Abstract ## Purpose To compare two methods for assessing the single kidney glomerular filtration rate (SK‐GFR) in humans using dynamic contrast‐enhanced (DCE)‐MRI. ## Materials and Methods Images were acquired from 39 separate MR studies of patients with atherosclerotic renovascular disease (