๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Forensic toxicologic analysis of methamphetamine and amphetamine optical isomers by high performance liquid chromatography

โœ Scribed by Nagai, T. ;Kamiyama, S.


Publisher
Springer-Verlag
Year
1988
Tongue
English
Weight
478 KB
Volume
101
Category
Article
ISSN
1437-1596

No coin nor oath required. For personal study only.

โœฆ Synopsis


Optical isomers (d and /) and racemic compounds (dl) of methamphetamine (MAMP) and amphetamine (AMP), and biologic materials including those substances, could be analyzed by high performance liquid chromatography. Examining the temperature for the analysis, 40ยฐC was the optimal condition in the reproducibility of separated MAMP-isomers. The reproducibility at the temperature did not vary significantly. The measured values of optical isomers were 0.116 _+ 0.012, 1.082 _+ 0.070 and 8.984 _+ 0.136 for the mixing ratios (l/d) of 0.111, 1.000, and 9.000, respectively. The detection limit for both d-and/-isomers was 25 ng.

The analytic result of hair specimens from two stimulant abusers by the present method indicates that they contained only d-MAMP and d-AMP, which is believed to have the strongest pharmacologic effect among the optical isomers of MAMP. The coefficient of variation in the analysis of five replicate standards, prepared by adding 1,000 ng each of racemate MAMP and AMP to hair, was less than 4%. The measured value against I/d = 1.000 was 1.040 _+ 0.040 in MAMP and 0.980 + 0.030 in AMP. The detection limit for both racemate MAMP and AMP accumulated in hair was 250 ng.

The analysis of the optical isomers by our method would contribute to identifying the smuggling routes or the illicit method.


๐Ÿ“œ SIMILAR VOLUMES


Forensic toxicologic analysis of methamp
โœ Hara, Kenji ;Nagata, Takeaki ;Kimura, Kojiro ๐Ÿ“‚ Article ๐Ÿ“… 1986 ๐Ÿ› Springer-Verlag ๐ŸŒ English โš– 594 KB

Qualitative and quantitative analysis of methamphetamine and amphetamine in biologic materials was carried out by gas chromatography/ mass spectrometry. A deuterium-labeled methamphetamine was employed as an internal standard with a detection limit of 50 pg and absolute stability and reproducibility

Sample preparation of amphetamine and me
โœ Jerzy Trocewicz ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 114 KB ๐Ÿ‘ 2 views

## Sample preparation of amphetamine and methamphetamine by means of supported liquid membrane technique for high-performance liquid chromatography analysis A technique for sample workup and enrichment using a supported liquid membrane (SLM) extraction and high-performance liquid chromatography (H

Analysis of triacylglycerol positional i
โœ Adlof, Richard O. ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 345 KB

## Abstract Silver ion chromatography, utilizing two commercially available HPLC columns connected in series, was used to separate a variety of triacylglycerol positional isomers. The isomers had a fatty acid composition of ABA and AAB, where A and B were fatty acids containing zero to three double