Qualitative and quantitative analysis of methamphetamine and amphetamine in biologic materials was carried out by gas chromatography/ mass spectrometry. A deuterium-labeled methamphetamine was employed as an internal standard with a detection limit of 50 pg and absolute stability and reproducibility
Forensic toxicologic analysis of methamphetamine and amphetamine optical isomers by high performance liquid chromatography
โ Scribed by Nagai, T. ;Kamiyama, S.
- Publisher
- Springer-Verlag
- Year
- 1988
- Tongue
- English
- Weight
- 478 KB
- Volume
- 101
- Category
- Article
- ISSN
- 1437-1596
No coin nor oath required. For personal study only.
โฆ Synopsis
Optical isomers (d and /) and racemic compounds (dl) of methamphetamine (MAMP) and amphetamine (AMP), and biologic materials including those substances, could be analyzed by high performance liquid chromatography. Examining the temperature for the analysis, 40ยฐC was the optimal condition in the reproducibility of separated MAMP-isomers. The reproducibility at the temperature did not vary significantly. The measured values of optical isomers were 0.116 _+ 0.012, 1.082 _+ 0.070 and 8.984 _+ 0.136 for the mixing ratios (l/d) of 0.111, 1.000, and 9.000, respectively. The detection limit for both d-and/-isomers was 25 ng.
The analytic result of hair specimens from two stimulant abusers by the present method indicates that they contained only d-MAMP and d-AMP, which is believed to have the strongest pharmacologic effect among the optical isomers of MAMP. The coefficient of variation in the analysis of five replicate standards, prepared by adding 1,000 ng each of racemate MAMP and AMP to hair, was less than 4%. The measured value against I/d = 1.000 was 1.040 _+ 0.040 in MAMP and 0.980 + 0.030 in AMP. The detection limit for both racemate MAMP and AMP accumulated in hair was 250 ng.
The analysis of the optical isomers by our method would contribute to identifying the smuggling routes or the illicit method.