๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Fluorometric analysis of pectenotoxin-2 in microalgal samples by high performance liquid chromatography

โœ Scribed by Katsunoti Sasaki; Azusa Takizawa; Aurelia Tubaro; Laura Sidari; Roberto Della Loggia; Takeshi Yasumoto


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
77 KB
Volume
7
Category
Article
ISSN
1056-9014

No coin nor oath required. For personal study only.

โœฆ Synopsis


A rapid HPLC method with ยฏuorescence detection of pectenotoxin-2 (PTX2), a polyether macrolide toxin, in microalgae is presented. A dienophile reagent, DMEQ-TAD, was used for precolumn ยฏuorescence labeling. PTX2 could be quantitatively detected in the range 1ยฑ200 ng. This method conยฎrmed the occurrence of PTX2 in net haul samples mostly composed of dinoยฏagellates Dinophysis spp. collected in the Adriatic Sea, Italy and Mutsu Bay, Japan.


๐Ÿ“œ SIMILAR VOLUMES


Analysis of eleven capsaicinoids by reve
โœ Marie-Noรซlle Maillard; Pierre Giampaoli; Hubert M. J. Richard ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 129 KB ๐Ÿ‘ 1 views

More than 90 dierent capsicums are found all over the world. They contain capsaicinoids, which are responsible for the hot and pungent ยฏavour. After extraction by a methanolยฑwater mixture (60 : 40, v/v) from capsicum oleoresins, 13 compounds were separated by analytical HPLC on a C18 Hypersil column

Analysis of 13 phenolic compounds in Alo
โœ M. K. Park; J. H. Park; Na Young Kim; Young Geun Shin; Yong Seok Choi; Jin Gyun ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 308 KB ๐Ÿ‘ 2 views

Thirteen phenolic compounds from Aloe barbadensis (syn. A. vera) and A. arborescens were analysed by high performance liquid chromatography, using a reverse phase column eluted with a methanol: water gradient, and detected by UV at 293 nm. Aloesin, 8-C-glucosyl-7-O-methyl-(S)-aloesol, neoaloesin A,

Sample preparation of amphetamine and me
โœ Jerzy Trocewicz ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 114 KB

## Sample preparation of amphetamine and methamphetamine by means of supported liquid membrane technique for high-performance liquid chromatography analysis A technique for sample workup and enrichment using a supported liquid membrane (SLM) extraction and high-performance liquid chromatography (H

Direct injection versus liquid-liquid ex
โœ Mohammed Jemal; Mike Huang; Xiaohui Jiang; Yan Mao; Mark L. Powell ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 131 KB ๐Ÿ‘ 2 views

Direct injection versus liquid-liquid extraction for post-dose human plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) have been studied using a drug candidate compound. For the direct-injection method, an Oasis 1 HLB column (1 ร‚ 50 mm, 30 mm)