𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Flow microcalorimetric assay of antibiotics—I. Polymyxin B sulphate and its combinations with neomycin sulphate and zinc bacitracin on interaction with Bordetella bronchiseptica (NCTC 8344)

✍ Scribed by N.Joslin Kjeldsen; A.E. Beezer; R.J. Miles


Book ID
103911060
Publisher
Elsevier Science
Year
1989
Tongue
English
Weight
551 KB
Volume
7
Category
Article
ISSN
0731-7085

No coin nor oath required. For personal study only.

✦ Synopsis


A flow microcalorimetric assay for polymyxin B sulphate has been developed which has a better reproducibility (relative standard deviation less than 3%) and sensitivity (0.35 micrograms ml-1) than conventional microbiological assays, and requires an assay time of ca. 4.5 h. The combinations with zinc bacitracin, with neomycin sulphate, and with both zinc bacitracin and neomycin sulphate indicate antagonism between these antibiotics upon interaction with Bordetella bronchiseptica (NCTC 8344). The combinations of all three antibiotics assayed were: (1) equimolar proportions; and (2) those proportions present in the commercial preparation TrisepR (ICI, Macclesfield, UK).


📜 SIMILAR VOLUMES


Flow microcalorimetric assay of antibiot
✍ N.Joslin Kjeldsen; A.E. Beezer; R.J. Miles 📂 Article 📅 1989 🏛 Elsevier Science 🌐 English ⚖ 372 KB

A flow microcalorimetric assay for Neomycin has been developed which is monitored through interaction of the antibiotic with Bacillus pumilus as the test organism. The assay has better reproducibility (relative standard deviation 2.3%) and is more sensitive than conventional microbiological bioassay

Flow microcalorimetric assay of antibiot
✍ N.Joslin Kjeldsen; A.E. Beezer; R.J. Miles 📂 Article 📅 1989 🏛 Elsevier Science 🌐 English ⚖ 376 KB

A flow microcalorimetric assay for zinc bacitracin has been developed which has better reproducibility (relative standard deviation less than 2%) and sensitivity (0.02 micrograms ml-1) than conventional microbiological assays, and requires an assay time of between 7.5-9 h. The assay is not suitable

Flow microcalorimetric assay of antibiot
✍ N.Joslin Kjeldsen; A.E. Beezer; R.J. Miles; H. Sodha 📂 Article 📅 1989 🏛 Elsevier Science 🌐 English ⚖ 356 KB

Flow microcalorimetric assays for polymyxin B sulphate and neomycin sulphate have been developed using Escherichia coli as the test organism, suspended in a glucose plus buffer medium. These assays have a better reproducibility (relative standard deviations 3.2 and 2.0%, respectively), and require a