A flow microcalorimetric assay for zinc bacitracin has been developed which has better reproducibility (relative standard deviation less than 2%) and sensitivity (0.02 micrograms ml-1) than conventional microbiological assays, and requires an assay time of between 7.5-9 h. The assay is not suitable
Flow microcalorimetric assay of antibiotics —IV. Polymyxin B sulphate, neomycin sulphate, zinc bacitracin and their combinations with Escherichia coli suspended in buffer plus glucose medium
✍ Scribed by N.Joslin Kjeldsen; A.E. Beezer; R.J. Miles; H. Sodha
- Book ID
- 103911063
- Publisher
- Elsevier Science
- Year
- 1989
- Tongue
- English
- Weight
- 356 KB
- Volume
- 7
- Category
- Article
- ISSN
- 0731-7085
No coin nor oath required. For personal study only.
✦ Synopsis
Flow microcalorimetric assays for polymyxin B sulphate and neomycin sulphate have been developed using Escherichia coli as the test organism, suspended in a glucose plus buffer medium. These assays have a better reproducibility (relative standard deviations 3.2 and 2.0%, respectively), and require a shorter time (1 h including time required for preparation of the calorimeter) than do conventional microbiological assays, but are not as sensitive. It is suggested that a screening programme might produce a small group of more suitable (i.e. more sensitive) test organisms, which could be used to develop rapid and reproducible flow microcalorimetric assays for a wide range of antibiotics by the procedure described. The effect of combinations of polymyxin B sulphate, neomycin sulphate and zinc bacitracin (the antibiotic components of the commercial preparation Trisep, ICI, Macclesfield, UK) on the power output of cells suspended in glucose plus buffer medium is also reported. In defined combinations, the effects of neomycin sulphate appeared to be exerted before those of polymyxin B sulphate.
📜 SIMILAR VOLUMES
A flow microcalorimetric assay for polymyxin B sulphate has been developed which has a better reproducibility (relative standard deviation less than 3%) and sensitivity (0.35 micrograms ml-1) than conventional microbiological assays, and requires an assay time of ca. 4.5 h. The combinations with zin
A flow microcalorimetric assay for Neomycin has been developed which is monitored through interaction of the antibiotic with Bacillus pumilus as the test organism. The assay has better reproducibility (relative standard deviation 2.3%) and is more sensitive than conventional microbiological bioassay