Chrommm(V1) can be determmed spectrophotometncally at 365 nm after flow-mjectlon extraction mto chloroform of the ion associate benzyltr~butyhunmonmm dlchromate The tamer stream was distilled water, merged with 10 M sulphunc acid solution, the reagent stream was 0 5% (w/v) benzyltnbutylammonmm chlon
Flow-injection extraction-spectrophotometric determination of manganese(VII) with benzyltributylammonium cations
โ Scribed by D. Thorburn Burns; S.A. Barakat; M. Harriott; M.S. El-Shahawi
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 201 KB
- Volume
- 270
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
โฆ Synopsis
A flow-injection manifold has been developed for the spectrophotometric determination of manganese(VII) at 548 nm after extraction into chloroform of the ion-associate, benzyltributylammonium permanganate. The carrier stream was a pH 6 buffer containing 10% (w/v) ammonium fluoride and the reagent stream was 0.10% (w/v) benzyltributylammonium chloride. The injection rate was 20 h 1. The calibration graph is linear up to 25/xg ml 1 and the detection limit (3 ร baseline noise) is 0.91 /zg ml -i Mn(VII), based on 250-/xl injection volumes. The system has been applied to the determination of manganese in steels and a cupro-nickel alloy.
๐ SIMILAR VOLUMES
ManganeseNII) (O-100 pg) can be determmed spectrophotometncally at 548 nm after Its extraction as benzyltr~butylammomum permanganate, at pH 6, mto chloroform The effects of pH, reagent concentrations and &verse ions are reported The system has been apphed to the detemunation of manganese m a vanety
We proposed a simple flow-injection spectrophotometric procedure for the determination of yttrium using Arsenazo III and optimized various conditions (pH for color formation and sample, buffer systems, Arsenazo III concentration, injection volume, flow-rate, and mixing coils). The calibration was li
The indirect spectrophotometric determination of 0.8-7.2 ppm calcium in the presence of magnesium, phosphate and sulphate by flow injection analysis (f.i.a.) is described. The method is based on the exchange reaction between the calcium and the zinc complex of ethylene glycol-bis(2aminoethylether)te
A flow-inJectIon spectrophotometnc method for the determmatlon of palladmm mvoives the measurement of the absorbance of the pallachum complex with DCS-arsenazo at 635 nm The cahbratlon graph IS hnear over the range O-8 0 pg ml-' The detectIon hrnlt IS 0 05 pg ml-1 The sample throughput IS 90 h-' wit