In this paper, an experimental study on the heat transfer characteristics of two-phase #ow boiling of alternative zeotropic refrigerant mixtures to R-502, on air/refrigerant horizontal enhanced surface tubing is presented. The new alternatives considered in this study are: R-507, R-404A, R-407B, and
Flow boiling and condensation of tetrary refrigerant mixtures inside water/refrigerant enhanced surface tubing
โ Scribed by S. M. Sami; B. Song
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 282 KB
- Volume
- 21
- Category
- Article
- ISSN
- 0363-907X
No coin nor oath required. For personal study only.
โฆ Synopsis
This work presents the results of an experimental study concerning the heat transfer characteristics of two-phase flow condensation and boiling of tetrary (R-32/R-125/R143a/R134a) refrigerant mixtures inside water/refrigerant horizontal enhanced surface tubing. Heat transfer characteristics such as average heat transfer coefficients, as well as pressure drops of the tetrary refrigerant mixtures, have been predicted and compared with other mixtures during flow condensation and boiling inside enhanced surface tubing. It was found that the tetrary refrigerant blend has higher transfer coefficients than R-502, and the lowest pressure drop among the refrigerants studied.
๐ SIMILAR VOLUMES
In this paper, an experimental study on the heat transfer characteristics of two-phase #ow boiling of alternative zeotropic refrigerant mixtures to R-22, on air/refrigerant horizontal enhanced surface tubing is presented. The new alternatives considered in this study are: R-507, R-404A, R-408A, R-40
In this paper, an experimental study on the heat transfer characteristics of two-phase #ow boiling of some alternative refrigerants to HCFC-22, on air/refrigerant horizontal enhanced surface tubing, is presented. Correlations have been proposed to predict the heat transfer characteristics such as av
In this paper, the test results of a performance analysis of new alternatives; R-410A, R-507, R-407C, R-408A and R-404A proposed as substitutes to HCFC-22 are presented. The test results were obtained using an air-source heat pump with enhanced surface tubing. Performance tests were conducted accord
In this paper the test results of a performance evaluation of new alternatives; R-407B, R-507, R-408A and R-404A as substitutes to CFC-502 are presented. The test results were obtained using an air-source heat pump with enhanced surface tubing under standard ARI conditions. The data demonstrated th