✦ Synopsis


Abstract

It has been shown previously that a significant reduction of the acoustic noise in standard, slow magnetic resonance imaging (MRI) sequences is achieved when the gradient pulses have long sinusoidal ramps. An improvement of this method is now presented for fast gradient echo (FLASH) and fast spin echo (RARE) sequences. The new strategy consists of using a sinusoidal readout pulse with no plateau and extending the phase encoding pulses to the entire readout period. The distribution of k‐space samples is no longer equidistant, and images have to be reconstructed with gridding. A reduction of the acoustic noise by 20–40 dBA was obtained with respect to standard sequences installed by the scanner manufacturer, which is 10–20 dBA better than that with the previously proposed method of sinusoidal ramps. J. Magn. Reson. Imaging 2001;13:960–966. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


GRASE (Gradient-and Spin-Echo) imaging:
✍ Koichi Oshio; David A. Feinberg 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 335 KB

## Abstract A fast multi‐section MR imaging technique is described. Gradient‐ and spin‐echo (GRASE) imaging utilizes the speed advantages of gradient refocusing while overcoming the image artifacts arising from static field inhomogeneity and chemical shift. Image contrast is determined by the T2 co

Prepolarized fast spin-echo pulse sequen
✍ C. Kegler; H.C. Seton; J.M.S. Hutchison 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 276 KB

## Abstract Clinical MRI systems use magnetic fields of at least 0.5T to take advantage of the increase in signal‐to‐noise ratio (SNR) with __B__~0~. Low‐field MRI apparatus is less expensive and offers the potential benefit of improved __T__~1~ contrast between tissues. The poor inherent SNR at lo

T2-weighted MRI of rectosigmoid carcinom
✍ Shuhei Yamashita; Takayuki Masui; Motoyuki Katayama; Kimihiko Sato; Nobuko Yoshi 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 278 KB

## Abstract ## Purpose To compare the abilities of T2‐weighted (T2W) imaging using respiratory‐triggered fast spin‐echo (RT‐FSE), breathhold fast‐recovery FSE (BH‐FRFSE), and BH single‐shot FSE (BH‐SSFSE) sequences without an endorectal coil to detect rectosigmoid carcinomas. ## Materials and Met

Determination of gradient magnetic field
✍ Frank G. Shellock; Mokhtar Ziarati; Dennis Atkinson; Dar-Yeong Chen 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 488 KB

The purpose of this study was to assess gradient magnetic-field-induced acoustic noise levels associated with the use of echo planar imaging (EPI) and three-dimensional fast spin echo (3D-FSE) pulse sequences. Acoustic noise measurements were obtained from two different high field-strength MR system

T2-weighted MRI of the female pelvis: Co
✍ Takayuki Masui; Motoyuki Katayama; Shigeru Kobayashi; Harumi Sakahara; Tatsuhiko 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 441 KB

## Abstract In 49 patients who had pelvic abnormalities, breath‐hold T2‐weighted fast‐recovery (FR)‐fast spin‐echo (FSE) (imaging time = 24 sec) and nonbreath‐hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four‐point scale) and quantitatively (using signal‐to‐noise ratios (SNRs)