Prepolarized fast spin-echo pulse sequence for low-field MRI

✍ Scribed by C. Kegler; H.C. Seton; J.M.S. Hutchison


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
276 KB
Volume
57
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Clinical MRI systems use magnetic fields of at least 0.5T to take advantage of the increase in signal‐to‐noise ratio (SNR) with B~0~. Low‐field MRI apparatus is less expensive and offers the potential benefit of improved T~1~ contrast between tissues. The poor inherent SNR at low field can be offset by incorporating prepolarizing field pulses with the MRI pulse sequence. The prepolarizing field does not need to be as homogeneous as the detection field, so it can be generated by a relatively inexpensive electromagnet. Prepolarizing hardware for a 0.01T MRI system was developed together with a prepolarized MRI pulse sequence that incorporates fast imaging techniques to reduce acquisition times by a factor of 5 relative to standard methods. Comparison images of test objects show that most of the enhanced SNR is retained with the fast method. Low‐field images of a human wrist acquired using the fast prepolarized method are also shown. Magn Reson Med 57:1180–1184, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


MRI of the lung: Value of different turb
✍ Melanie Bruegel; Jochen Gaa; Klaus Woertler; Carl Ganter; Simone Waldt; Claudia 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 343 KB

## Abstract ## Purpose To compare the value of different MRI sequences of the lung for the detection of pulmonary metastases. ## Materials and Methods A total of 28 patients with 225 pulmonary metastases confirmed at multidetector‐row computed tomography (MDCT) underwent MRI of the lung, includi

Impact of motion on T1 mapping acquired
✍ Ueli Studler; Lawrence M. White; Gustav Andreisek; Sheena Luu; Hai-Ling Margaret 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 1 views

## Abstract ## Purpose: To evaluate the impact of motion on T1 values acquired by using either inversion‐recovery fast spin echo (IR‐FSE) or three‐dimensional (3D) spoiled gradient recalled‐echo (SPGR) sequences for delayed gadolinium‐enhanced magnetic resonance imaging of cartilage (dGEMRIC) in v

Evolution of the longitudinal magnetizat
✍ Simon J. P. Meara; Gareth J. Barker 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 75 KB 👁 1 views

## Abstract The fast spin‐echo (FSE) sequence is frequently used as a fast data‐readout technique in conjunction with other pulse sequence elements, such as in fluid‐attenuated inversion‐recovery (FLAIR) and double inversion‐recovery (DIR) sequences. In order to implement those pulse sequences, an

Meara SJP and Barker GJ. Evolution of th
📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 24 KB 👁 1 views

## Abstract The original article to which this Erratum refers was published in Magnetic Resonance in Medicine (2005) 54(1) 241–245.