𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fast and accurate analysis of drugs using amperometry associated with flow injection analysis

✍ Scribed by Fabiana S. Felix; Lúcio Angnes


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
348 KB
Volume
99
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.

✦ Synopsis


This review presents a general overview about the amperometric detection potentialities associated to flow injection analysis (FIA). Fundamental aspects, developments, applications and advantages accrued from the coupling of voltammetry with FIA for pharmaceutical analyses are discussed. The selected references present several examples for this association in various classes of drugs and support their advantages. Examples illustrate that the amperometric techniques coupled with flow system can usually be used in drug routine analysis without sample pretreatment. Amperometry/FIA has proved to be an excellent alternative to the chromatographic techniques and it has been used in routine analysis, from the simplest analytes to more complex species, solving even special cases such as the enantiomeric analysis of pharmaceutical compounds with a chiral moiety, which requires time-consuming sample preparation or expensive instrumentation. This revision also aims to contribute for reducing the gap between the vast possibilities enabled by electroanalytical techniques and their effective utilization for pharmaceutical analysis.


📜 SIMILAR VOLUMES


Measurement of protein using flow inject
✍ Lawrence C. Davis; Gary A. Radke 📂 Article 📅 1987 🏛 Elsevier Science 🌐 English ⚖ 382 KB

We have used the bicinchoninic acid reagent developed by Pierce Chemical Co. to measure proteins in a simple flow injection analyzer. The sensitivity is comparable to that of the Lowry method and no pipetting of reagents is needed. Results are obtained in less than 1 min and samples may be run at a

Studies of drug—protein binding interact
✍ G.L. Abdullahi; J.N. Miller; H.N. Sturley; J.W. Briges 📂 Article 📅 1983 🏛 Elsevier Science 🌐 English ⚖ 498 KB

The applicability of single-channel and merging-zones flow injection systems with fluorimetric detection to the study of drug-protein binding interactions has been demonstrated. A study of the binding of the fluorescent probe 8-anilinonaphthalene-1-sulphonic acid (ANS) to human serum albumin by mean

Simultaneous determination of fluoride a
✍ John R. Farrell; Peter J. Iles; Terry J. Sands 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 116 KB 👁 2 views

The design, development, and testing of a flow-injection analysis (FIA) manifold for the simultaneous determination of two species in water samples are reported. Fluoride is determined potentiometrically, and, following on-line sample dilution and treatment, amperometric analysis of phenolics is per

Flow-injection analysis with chemilumine
✍ Jin-Ming Lin; Toshiyuki Hobo 📂 Article 📅 1996 🏛 Elsevier Science 🌐 English ⚖ 464 KB

A simple flow-injection system with chemiluminescent detection for selective determination of sulphite is described. The light accompanying the reaction between sodium carbonate and copp&II) mixture solution with sulphite is detected. The concentration of sulphite is proportional to the chemilumines