A #exible sleeve can be considered as a new feature of the proposed active journal bearing. Variation of the oil pressure in the chamber located under the sleeve causes deformation of the sleeve and consequently changes the geometry of the oil "lm as well as the pressure distribution of the oil "lm.
EXPERIMENTAL MEASUREMENT OF PRECISION BEARING DYNAMIC STIFFNESS
β Scribed by E.R. Marsh; D.S. Yantek
- Publisher
- Elsevier Science
- Year
- 1997
- Tongue
- English
- Weight
- 201 KB
- Volume
- 202
- Category
- Article
- ISSN
- 0022-460X
No coin nor oath required. For personal study only.
β¦ Synopsis
Static stiffness measurement of precision bearing components by influence coefficients is complicated by the task of loading and measuring the baseline test fixture stiffness before including the bearing components. Furthermore, as the displacement of the bearing system is measured for various load conditions, the stiffness of high quality bearings may be difficult to distinguish from the test fixture stiffness. The common occurrence of inaccurate stiffness measurements has motivated this investigation of an experimental method based on frequency response function measurements. In this work the traditional static measurement that requires careful attachment and modelling of the test fixture to ''ground'' is abandoned and replaced by dynamic measurements taken from a test fixture with free boundary conditions. A complete dynamic characterization of the test fixture is shown to be unnecessary; the only measurements required are the frequency response functions at the points of attachment to the bearing components. An investigation into the effects of common measurement errors such as sensor calibration and location is also included, with an example of the proposed method.
π SIMILAR VOLUMES
The complex stiffness of resilient elements is an important parameter required in order to model vibration isolation for many applications. Measurement methods are being standardized which allow such a stiffness to be measured as a function of excitation frequency for known loading conditions. This
## Abstract ## Purpose To examine the sensitivity of quantitative dynamic contrast enhanced MRI (DCEβMRI) perfusion maps to errors in the various source images and to determine optimal imaging parameters for reducing this sensitivity. ## Materials and Methods A detailed analysis of the precision
## Abstract Dynamic contrastβenhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because