Polymerized 2-cyanoethyl methacrylate (KEM) has been tested as a stationary phase for gas-solid chromatography. Its thermal stability has been investigated and the usable range defined. The specific retention volumes, V,,, of the C1-Cs fatty acids and water have been measured and some thermodynamic
Evaluation of various HILIC materials for the fast separation of polar compounds
✍ Scribed by Bénédicte Chauve; Davy Guillarme; Philippe Cléon; Jean-Luc Veuthey
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 405 KB
- Volume
- 33
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In recent years, numerous works have been reported on hydrophilic interaction chromatography (HILIC) columns, but there is a growing demand for fast separations with improved resolution. Such analyses can only be obtained with the new generation of columns and instrumentation. In the present study, HILIC columns packed with porous sub‐2 μm particles or with superficially porous particles of 2.7 μm were evaluated. A set of 15 compounds with diverse physicochemical properties was selected. The aim of this study was to compare the chromatographic behavior of three selected columns. Concerning kinetic performance, the fused‐core column offers a backpressure two times lower than the sub‐2‐μm particle columns. However, these superficially porous particles also generated a 30% lower efficiency. The complex mechanism of HILIC was also investigated on bare silica columns, confirming that the mechanism is a mixture of partitioning, adsorption and ion exchange in different proportions according to the nature of the analytes, the composition of the mobile phase and the characteristics of the analytical support. Finally, a rapid separation of three drugs and their corresponding metabolites was carried out. The analysis time was reduced to less than 4 min while maintaining acceptable backpressure and sufficient resolution.
📜 SIMILAR VOLUMES
## Abstract Methods of prospective evaluation of the use of various materials as active elements for quantum generators for certain applications are considered. The way of evaluation for all kinds of dielectric crystal lasers with respect to optical quantum generators, applicable in technical desig
The utility of negatively charged sulfated cyclodextrins (SCD) as chiral additives (CA) in capillary electrophoresis (CE) was studied in the chiral resolution of several compounds of pharmaceutical interest, including catecholamines such as norepinephrine, epinephrine, DOPA and their precursors, phe