Evaluation of the Sysmex Xe-2100® hematology analyzer in hospital use

✍ Scribed by Danièle Nakul-Aquaronne; Isabelle Sudaka-Sammarcelli; Corinne Ferrero-Vacher; Benoit Starck; Jacques Bayle


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
155 KB
Volume
17
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The Sysmex XE‐2100^®^ (Sysmex Corp. Kobe, Japan) is a latest‐generation hematology analyzer. Its optical and electrical measuring technology is improved by the addition of flux cytometry, fluorescence, and differential lysis. Its analytical performance in terms of precision, reproducibility, linearity, carryover, and time stability was found to be entirely satisfactory. In addition, the results of 500 complete blood counts and differentials correlated perfectly with those obtained by the Coulter STKS^®^ (Beckman Coulter, Villapointe, France). The comparison of 500 leukocyte differential count results analyzed in parallel with optical microscopy and the XE‐2100^®^ were surprising, and favorable to the XE‐2100^®^. This analyzer provides the user with an undeniable feeling of security concerning its reliability in detecting and identifying anomalies in the automated leukocyte differential count. With a sensitivity of 96%, a negative predictive value (NPV) of 98%, and a false‐negative (FN) rate of 4%, the XE‐2100^®^ has perhaps reached the technological limits for a machine performing morphological recognition of normal and pathological blood cells. J. Clin. Lab. Anal. 17:113–123, 2003. © 2003 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Automatic analysis of normal bone marrow
✍ Hisako Shibata; Takahisa Yamane; Ryousuke Yamamura; Kensuke Ohta; Takayuki Takub 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 133 KB

## Abstract The bone marrow aspiration test conventionally has been performed by visual methods, using a light microscope, because automatic blood cell analyzers cannot adequately capture erythroblasts and immature granulocytes (IGs) (Tatsumi et al.: Osaka City Med J 1988;34:135–146; Tatsumi et al.

Evaluation of the Beckman Synchron cx4 c
✍ T. Ambus; N. Korogyi; F. Decampos; B. Groom; V. T. Innanen 📂 Article 📅 1990 🏛 John Wiley and Sons 🌐 English ⚖ 511 KB

The Beckman Synchron CX4 randomaccess multianalyzer was evaluated in a medium sized hospital laboratory. The instrument does end-point, rate, and multipoint assays and carries on-board reagents for 24 tests. In addition to predefined tests, the instrument can be programmed for 100 userdefined tests;

Modeling seasonal variation in rotavirus
✍ Takanori Sato; Toyoko Nakagomi; Mohammadreza Naghipour; Osamu Nakagomi 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 259 KB

## Abstract Every year rotavirus epidemic repeats in cooler months of the year in temperate countries, but the size of the epidemic may often vary. Such seasonal variation needs to be considered when the effect of rotavirus vaccine is predicted before vaccine introduction or it is evaluated after v