✦ Synopsis


Abstract

Quantitativeness of matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) was elucidated using an equimolar mixture of uniform poly(ethylene glycol) (PEG) oligomers with no molecular weight distributions. Uniform PEG oligomers with degrees of polymerization n = 6–40 were separated from commercial PEG samples by preparative super‐critical fluid chromatography. MALDI‐TOF mass spectra of an equimolar mixture of the uniform PEG oligomers were recorded by adding a mixture of 2,5‐dihydroxybenzoic acid as a matrix reagent and four chlorinated salts, i.e. LiCl, NaCl, KCl and RbCl. Remarkable non‐quantitative effects were observed in the MALDI‐TOF mass spectra in both the lower and higher molecular mass regions. At higher molecular masses greater than about 10^3^, PEG oligomers with larger molecular mass yielded lower spectral intensities irrespective of the species of adduct cations and higher laser powers induced larger decreases in mass spectral intensities with the increase in their molecular masses. On the other hand, in the lower molecular mass region, less than about 10^3^, the observed non‐quantitative effect greatly depends on the species of adduct cations, indicating that the stability of the PEG–cation complex affects the MALDI‐TOF mass spectral intensities of uniform PEG oligomers. Copyright © 2003 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Poly(ethylene glycol) limits of detectio
✍ Pastor, Salvador J.; Wood, Sylvia H.; Wilkins, Charles L. 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 309 KB 👁 2 views

Detection limits of poly(ethylene glycol) were examined in the mass range 2000-6000 Da. Using an aerospray sample deposition technique, highly uniform sample surfaces were produced. This method allows signal averaging of spectra from up to 400 shots on the same sample spot. It is found that, as the

Characterization of partially transester
✍ K. A. Saeed; F. O. Ayorinde; B. E. Eribo; M. Gordon; L. Collier 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 91 KB

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used for the characterization of a partially transesterified poly(b-hydroxyalkanoate), PHA, polymer produced by the bacterial strain Alcaligenes eutrophus using saponified vegetable oils as the sole carbon