Characterization of partially transesterified poly(β-hydroxyalkanoate)s using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
✍ Scribed by K. A. Saeed; F. O. Ayorinde; B. E. Eribo; M. Gordon; L. Collier
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 91 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
✦ Synopsis
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used for the characterization of a partially transesterified poly(b-hydroxyalkanoate), PHA, polymer produced by the bacterial strain Alcaligenes eutrophus using saponified vegetable oils as the sole carbon sources. The transesterification was carried out separately under acidic and basic conditions to obtain PHA oligomers weighing less than 10 kDa. The intact oligomers were detected in their cationized [M Na] and [M K] forms by MALDI-TOFMS. A composition analysis, using the MALDI-TOF spectra, indicate that the oligomers obtained via acid catalysis were terminated with a methyl 3-hydroxybutyrate end group, and those obtained by base catalysis had a methyl crotonate (olefinic) termination. In addition to HB (hydroxy butyrate), the oligomers were found to contain a small percentage of HV (hydroxy valerate). This was independently confirmed using gas chromatography/mass spectrometry (GC/MS). In comparison, the analysis of a commercial PHA polymer, transesterified under identical conditions, only showed the presence of HB, i.e. a pure PHB homopolymer.
📜 SIMILAR VOLUMES
The ionization of nucleosides in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was systematically investigated using adenine (A), thymine (T), guanine (G) and cytosine (C) with several common matrices. Experimental results of the protonation and deprotonation of the ba
A variety of gram-positive and gram-negative intact bacterial cells have been analysed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and shown to provide fingerprint mass spectra with discrete peaks being observed over the mass range from 3 to 40 kDa. The spectra show b
Chemical degradation methods combined with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) and post-source decay (PSD)-MALDI reflex TOF mass spectrometry (MS) were used to determine the sequence of a peptide branched on to a known peptide backbone. This study was applied to a
The limits of performance of a linear time-of-flight mass spectrometer using matrix-assisted laser desorp tionlionization have been tested. Effects of the pressure in the vacuum system and the sampling rate of the digital oscilloscopes on mass resolution have been investigated. Spectra recorded at d