𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of the polarity of packed and capillary columns by different classification methods

✍ Scribed by G. Castello; G. D'Amato; S. Vezzani


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
704 KB
Volume
646
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Temperature dependence of equivalent cha
✍ Sidisky, Leonard M. ;Ridley, Heloise J. πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 436 KB

## Abstract The influence of temperature and capillary column stationary phase polarity on the equivalent chain length (ECL) values of unsaturated fatty acid methyl esters (FAMEs) is discussed. Comparisons are made of a bonded, nonpolar methyl silicone, bonded and nonbonded polyethylene glycols, an

Prediction of programmed temperature ret
✍ Gerbino, Tomaso C. ;Costello, Gianrico πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 654 KB

## Abstract Systems formed by serial connection of capillary columns of different polarity were studied with methods previously used to predict the behavior of linked capillary columns under isothermal conditions and to obtain programmed temperature gas chromatography (PTGC) retention times of the

Preparation and evaluation of supercriti
✍ Daixin Tong; Keith D. Bartle; Anthony A. Clifford πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 537 KB

## Abstract Preparation of packed capillary columns with supercritical carbon dioxide as the packing carrier is demonstrated; column performance was evaluated by both HPLC and SFC. It is shown that this procedure yields excellent column performance. The density of the packed bed can be controlled b

On the stability of micro-LC columns (pa
✍ De Weerdt, M. ;Dewaele, C. ;Verzele, M. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 316 KB

The life expectancy and resistance to flow, pressure shocks, solvent gradients, and bending of packed fused silica capillary columns (Micro-LC) are discussed. ## 2 Instrumentation Chromatographic measurements were carried out on a Varian 5020 (Varian Associates, Walnut Creek, CA, USA) and on a Per

On the efficiency of capillary columns c
✍ David, F. ;Proot, M. ;Sandra, P. πŸ“‚ Article πŸ“… 1985 πŸ› John Wiley and Sons 🌐 English βš– 435 KB πŸ‘ 1 views

The efficiency of FSOT columns coated with thick films of polyphenylmethylsiloxane was theoretically and experimentally compared to thin apolar and medium polar coatings and to thick apolar coatings. Experimental hli and TZG plots clearly demonstrate the enormous loss in chromatographic efficiency o