𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of Signal Processing Methods for the Quantification of Strongly Overlapping Peaks in 31P NMR Spectra

✍ Scribed by C. Decanniere; P. Vanhecke; F. Vanstapel; H. Chen; S. Vanhuffel; C. Vandervoort; B. Vantongeren; D. Vanormondt


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
523 KB
Volume
105
Category
Article
ISSN
1064-1866

No coin nor oath required. For personal study only.

✦ Synopsis


A time series of (16{ }^{31} \mathrm{P}) NMR spectra of rat liver perfused with 2,5-anhydro-D-mannitol has been quantitatively analyzed by two types of model function fitting algorithms in the time domain: an iterative least-squares fitting procedure (VARPRO) and a noniterative singular-value-decomposition-based method, combined with minimum-variance preprocessing (MV-HTLS). MVHTLS, which does not allow the incorporation of prior knowledge, is unreliable for the quantification of overlapping peaks at low signal-to-noise ratio. Although the overall fit is good, i.e., the residue is small, the fitted parameters do not accurately represent the individual components. The incorporation of prior knowledge about the model parameters results in a significant gain in precision of VARPRO. G: 1994 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


Evaluation of signal processing methods
✍ K. Overloop; P. Van Hecke; F. Vanstapel; H. Chen; S. Van Huffel; A. Knijn; D. va πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 786 KB

The "C-l NMR peak in proton-decoupled spectra of liver glycogen solution was quantitatively analyzed by three types of model-function fitting algorithms: iterative line-fitting in the frequency domain (MDCON); iterative least-squares fitting (VARF'RO) in the time domain; and noniterative singular va

Accurate quantification of in vivo31P NM
✍ J. W. C. van der Veen; R. de Beer; P. R. Luyten; D. van Ormondt πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 416 KB

Free induction decay signals are analyzed by fitting a model function directly in the time domain. No starting values are needed for linear model parameters, and omission of corrupted data points poses no problems. A significant gain of accuracy is achieved by imposing prior knowledge about the mode

Improved quantification of in vivo1H NMR
✍ A. A. De Graaf; W. M. M. J. BovΓ©e πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 851 KB

## Abstract Quantification of localized __in vivo__ brain ^1^H spectra is in general very difficult due to excessive spectral overlap. In addition, intensity distortions may result from the effects of the NMR pulse sequence on the spins. This paper describes an approach to solving these problems. I

Concurrent quantification of tissue meta
✍ Jeffrey J. Neil; Sheng-kwei Song; Joseph J. H. Ackerman πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 710 KB

## Abstract The deuterium washout technique of measuring tissue blood flow is based upon NMR detection of HOD (administered as D~2~O saline, but typically detected as HOD because of rapid proton‐deuteron exchange) as a freely diffusible tracer. Though this method is coming into more general use, it