Four volunteers were exposed dermally to styrene vapours within the concentration range of 1300 to 3200 mg/m 3 The increase in the levels of mandelic and phenylglyoxylic acids in urine after exposure was strongly noticeable The dermal vapour absorption coefficient (a) was calculated: for styrene it
Evaluation of low exposure to styrene
โ Scribed by H. Wieczorek; J. K. Piotrowski
- Publisher
- Springer-Verlag
- Year
- 1985
- Tongue
- English
- Weight
- 681 KB
- Volume
- 57
- Category
- Article
- ISSN
- 0340-0131
No coin nor oath required. For personal study only.
โฆ Synopsis
Volunteers (six men and one woman) were exposed by inhalation to styrene within the concentration range of 20 to 200 mg/m 3 The average retention of styrene vapours in the respiratory tract was 71 % The yield of styrene metabolism measured within 24 h was 39 and 17 % for mandelic acid and phenylglyoxylic acid, respectively The determination of mandelic acid in urine collected immediately after the exposure was applied as exposure test The excretion rate of this metabolite assured the best correlation with the absorbed dose The relative standard deviations of the test related to acutal dose level vary, depending on the analysed concentration range, from 0.21 to 0 33 Quantitative interpretation of the test is possible for styrene concentrations in the air exceeding 20 mg/m 3 The concentration amounting to 100 mg/m 3 (TLV) corresponds with the mandelic acid excretion rate of 15 mg per hour.
๐ SIMILAR VOLUMES
The derivatization of phenylglyoxylic acid (PGA), a urinary styrene metabolite, gives with diazomethane under ordinary reaction conditions secondary products as expected from the behaviour of other -keto acids Thus reproducible quantitative analysis becomes difficult It is shown that by proper selec
A simple and specific method for the quantitative gaschromatographic (GC) analysis of mandelic and phenylglyoxylic acid (MA and PGA), human urinary styrene metabolites, is described MA is determined by trimethylsilylation and subsequent GC analysis Because of difficulties involved in the direct dete