𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Evaluation of a local microsphere injection method for measurement of blood flow in the rabbit lower extremity

✍ Scribed by Yutaka Maki; Warren C. Breidenbach; Dr. John C. Firrell


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
718 KB
Volume
11
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The precision of a modified microsphere technique to measure blood flow in the hind limb of the rabbit was determined. Regional (local) injections made via a catheter in the aorta and blood withdrawn through a catheter in the hind limb enabled deposition of a high concentration of microspheres in the tissues while minimizing the number of microspheres needed for accurate measurement. ^95^Niobium and ^141^cerium‐labeled 16 ΞΌm diameter microspheres were used. Blood flow was measured in 15 locations of muscle and skin for simultaneous injections into the aorta and left ventricle (group A), simultaneous injections of a mixture into the left ventricle (group B), and ventricular injections given 1 h apart (group C). No significant differences in mean blood flow measurements were found. Correlation coefficients between local and ventricular injections ranged from 0.89–0.99 and between 0.994 and 0.999 for two simultaneous ventricular injections. The variability over time was greater, with correlations between the first and second injections ranging from 0.13–0.939. Precision of the local technique compared with the ventricular technique can be kept within 30% with five or six animals. The advantage of this technique over ventricular injections is in the measurement of blood flow in small tissue samples when the number of microspheres deposited from ventricular injections is insufficient.


πŸ“œ SIMILAR VOLUMES


Laser doppler flowmetry for bone blood f
✍ Dr. Marc F. Swiontkowski; S. Tepic; S. M. Perren; R. Moor; R. Ganz; B. A. Rahn πŸ“‚ Article πŸ“… 1986 πŸ› Elsevier Science 🌐 English βš– 851 KB

Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral head and femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and 85Sr-labeled microspheres were made in an adult rabbit model. There was

Measurement of blood flow to the tibial
✍ Dr. Paul D. Triffitt; Paul J. Gregg πŸ“‚ Article πŸ“… 1990 πŸ› Elsevier Science 🌐 English βš– 420 KB

## Abstract The commonly used size of microsphere for bone blood flow estimation is 15 ΞΌm, because it has appeard to be the smallest size that is not subject to significant nonentrapment in bone. Soft‐tissue studies suggest that it is microspheres of 9‐10 ΞΌm or less that pass through peripheral tis

A flow injection electrospray ionization
✍ David W. Johnson πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 129 KB

## Abstract Key metabolites for the diagnosis of the genetic disorder trimethylaminuria are trimethylamine (TMA) and trimethylamine __N__‐oxide (TMAO). A rapid, automatable flow injection ESI‐MS/MS method for their measurement in urine has been developed. The TMA was derivatized with ethyl bromoace