𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A flow injection electrospray ionization tandem mass spectrometric method for the simultaneous measurement of trimethylamine and trimethylamine N-oxide in urine

✍ Scribed by David W. Johnson


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
129 KB
Volume
43
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Key metabolites for the diagnosis of the genetic disorder trimethylaminuria are trimethylamine (TMA) and trimethylamine N‐oxide (TMAO). A rapid, automatable flow injection ESI‐MS/MS method for their measurement in urine has been developed. The TMA was derivatized with ethyl bromoacetate to form ethyl betaine bromide. The 2 min ESI‐MS/MS analysis employed four multiple reaction monitoring (MRM) ion pairs for derivatized TMA (146.1, 118.1), derivatized ^2^H~9~‐TMA (155.1, 127.1), TMAO (76.1, 58.1) and ^2^H~9~‐TMAO (85.1, 66.1). In control urine samples (n = 27) referred for suspected metabolic problems TMA was 0.11–1.19 mmol/mol creatinine, TMAO was 13.5–181 mmol/mol creatinine and the TMA/TMAO ratio was 0.0025–0.055. In five patients with diagnosed trimethylaminuria, TMA was 5.3–230 mmol/mol creatinine, TMAO was 0.36–607 mmol/mol creatinine and the TMA/TMAO ratio was 0.20–134. Copyright © 2007 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Simple, sensitive and rapid liquid chrom
✍ N. V. S. Ramakrishna; K. N. Vishwottam; S. Puran; S. Manoj; M. Santosh; M. Kotes 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 159 KB 👁 1 views

## Abstract A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simp

A new high-performance liquid chromatogr
✍ Laura Sabatini; Anna Barbieri; Marco Tosi; Francesco Saverio Violante 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 137 KB

## Abstract A new high‐performance liquid chromatographic/electrospray ionization tandem mass spectrometric (HPLC/ESI‐MS/MS) method was developed for the simultaneous quantification of 5‐fluorouracil (5FU), methotrexate (MTX) and cyclophosphamide (CP) in environmental samples. These compounds, comm

A sensitive and selective liquid chromat
✍ S. Sabarinath; M. Rajanikanth; K. P. Madhusudanan; R. C. Gupta 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 194 KB 👁 1 views

## Abstract A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of α‐,β‐arteether (α‐,β‐AE) and its metabolite α‐dihydroartemisinin (DHA) in monkey plasma using