𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Electrospray ionization tandem mass spectrometry for poly(propylene oxide) starting and end group analysis

✍ Scribed by Andrzej Stolarzewicz; Dorota Neugebauer; Jerzy Silberring


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
120 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Electrospray ionization tandem mass spectrometry was applied to study poly(propylene oxide) obtained in the presence of potassium hydride. It was found that the polyether chains possess different starting groups, i.e. those situated at the beginning of the polymer backbone. These were isopropoxy, hydroxy, methoxy and allyloxy groups when the polymerization was stopped by the addition of methyl iodide. Each macromolecule was terminated by the methoxy group in this case.


πŸ“œ SIMILAR VOLUMES


Electrospray tandem mass spectrometry of
✍ Zbigniew JedliΕ„ski; GraΕΌyna Adamus; Marek Kowalczuk; Ralf Schubert; Zbigniew Sze πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 125 KB πŸ‘ 2 views

The electrospray ionization tandem mass spectrometry technique applied for the first time to aliphatic polyester analysis, allowed fast and reliable identification of the various macromolecules of poly(3hydroxybutanoic acid) (PHB), synthesized via ring-opening polymerization of b-butyrolactone. It w

On-line derivatization of peptides for i
✍ M. S. CΓ‘rdenas; E. van der Heeft; A. P. J. M. de Jong πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 152 KB πŸ‘ 1 views

An on-line method has been developed for the derivatization and coupled liquid chromatography (LC)/electrospray ionization (ESI) MS analysis of peptides at the femtomol level. Peptides are reacted with N-succinimidyl-2(3-pyridyl)acetate (SPA) in buffered aqueous medium at pH 7 following loading on a

Utilizing Time-lag Focusing Matrix-assis
✍ Anthony T. Jackson; Hilary T. Yates; Chris I. Lindsay; Yves Didier; John A. Sega πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 236 KB πŸ‘ 1 views

Time-lag focusing matrix-assisted laser desorption/ionization mass spectrometry has been employed to analyse synthetic polymers with average molecular weights between approximately 3500 and 12 500 Da. Spectra are shown that demonstrate the improvement in resolution and sensitivity when time-lag focu

A comparison of matrix-assisted laser de
✍ Pierre Escoubas; Julia Chamot-Rooke; Reto StΓΆcklin; Brian J. Whiteley; Gerardo C πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 129 KB πŸ‘ 1 views

The search for novel pharmacological tools in spider venoms involves the need for precise and reproducible species identification methods. As an addition to morphological analysis, we have developed venom fingerprinting by reversed-phase chromatography and matrix-assisted laser desorption/ionization

Positive ion electrospray ionization tan
✍ Robert L. St. Claire III πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 107 KB

A novel analytical procedure has been developed for the analysis of intracellular nucleotide triphosphates. Positive ion electrospray ionization tandem mass spectrometry (MS/MS) was interfaced to ion-pairing highperformance liquid chromatography (HPLC) utilizing a mobile phase containing 10 mM ammon