๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Electrospray ionization mass spectrometry of platinum anticancer agents

โœ Scribed by G. K. Poon; P. Mistry; S. Lewis


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
512 KB
Volume
20
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Electrospray ionization mass spectrometr
โœ Vandell, Victor E.; Limbach, Patrick A. ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 373 KB ๐Ÿ‘ 2 views

The magnesium, nickel, copper, zinc and vanadium metalloporphyrins from octaethylporphyrin, etioporphyrin I and tetraphenylporphyrin were characterized using electrospray ionization mass spectrometry (ESI-MS). The ion abundance of each of the porphyrins present in binary mixtures was monitored as a

Electrospray ionization mass spectrometr
โœ Xiu-Sheng Miao; Chris D. Metcalfe; Chunyan Hao; Raymond E. March ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 481 KB

Ginsenosides R(b1), R(b2), R(c), R(d), R(e), R(f), R(g1), R(g2) and F(11) were studied systematically by electrospray ionization mass spectrometry in positive- and negative-ion modes with a mobile-phase additive, ammonium acetate. In general, ion sensitivities for the ginsenosides were greater in th

Preparative mass spectrometry with elect
โœ Siuzdak, Gary; Hollenbeck, Thomas; Bothner, Brian ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 42 KB ๐Ÿ‘ 2 views

## Preparative Mass Spectrometry with Electrospray Ionization In the early 1940s, E. O. Lawrence developed a mass spectrometry-based separation approach to enrich radioactive uranium 235 U from the natural isotopic distribution of uranium. 1 -3 This method used Calutron 3 mass spectrometers to sep

Electrospray ionization mass spectrometr
โœ Junhua Wei; Ji Chen; Jack Martin Miller ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 235 KB ๐Ÿ‘ 2 views

A detailed study of the solution chemistry and mass spectrometry of six carboxylato-organogermanium compounds in aqueous solution has been carried out using electrospray ionization and MS n techniques. The different types of hydrolysis products and their probable structures, which include the oligom

Electrospray Ionization Mass Spectrometr
โœ Christina B. Jasieczek; Armelle Buzy; David M. Haddleton; Keith R. Jennings ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 463 KB ๐Ÿ‘ 2 views

The effect of cone voltage on the polymer mass distribution of non-polar poly(styrene) samples has been investigated using electrospray ionization. It was found that relatively high cone voltages (120 V) were required to ionize non-polar polymers. At lower cone voltages (30-60 V), cluster ions, e.g.

Determination of micelle mass by electro
โœ Daisuke Nohara; Takatomo Kajiura; Koji Takeda ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 110 KB ๐Ÿ‘ 1 views

## Abstract By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to meas