Effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of analytes in liquid chromatographic/ionspray tandem mass spectrometric determination
✍ Scribed by Jamie J. Zhao; Amy Y. Yang; J. Douglas Rogers
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 190 KB
- Volume
- 37
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.299
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The effects of liquid chromatography mobile phase buffer contents on the ionization and fragmentation of drug molecules in liquid chromatographic/ionspray tandem mass spectrometric (LC/MS/MS) determination were evaluated for simvastatin (SV) and its hydroxy acid (SVA). The objective was to improve further the sensitivity for SV by overcoming the unfavorable condition caused by the formation of multiple major adduct ions and multiple major fragment ions when using ammonium as LC mobile phase buffer. Mobile phases (70:30 acetonitrile–buffer, 2 mM, pH 4.5) with buffers made from ammonium, hydrazine or alkyl (methyl, ethyl, dimethyl or trimethyl)‐substituted ammonium acetate were evaluated. Q1 scan and product ion scan spectra were obtained for SV in each of the mobile phases under optimized conditions. The results showed that, with the alkylammonium buffers, the alkylammonium‐adducted SV was observed as the only major molecular ion, while the formation of other adduct ions ([M + H]^+^, [M + Na]^+^ and [M + K]^+^) was successfully suppressed. On the other hand, product ion spectra with a single major fragment ion were not observed for any of the alkylammonium‐adducted SVs. The affinity of the alkylammoniums to SV and the basicity of the alkylamines are believed to be factors influencing the formation and abundance of molecular and fragment ions, respectively. Methylammonium acetate provided the most favorable condition among all the buffers evaluated and improved the sensitivity several‐fold for SV in LC/MS/MS quantitation compared with that obtained using ammonium acetate buffer. Better precision for SV in both Q1 and SRM scans was observed when using methylammonium buffer compared with those using ammonium buffer. The mobile phase buffer contents did not seem to affect the ionization, fragmentation and chromatography of SVA. The results of this evaluation can be applied to similar situations with other organic molecules in ionspray LC/MS/MS determination. Copyright © 2002 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract A method based on solid‐phase extraction coupled to liquid chromatography with positive ion electrospray ionization and tandem mass spectrometric detection was developed for the determination of didanosine in human serum, using lamivudine as internal standard. The acquisition was perfor
A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for