Fully automated determination of eserineN-oxide in human plasma using on-line solid-phase extraction with liquid chromatography coupled with electrospray ionization tandem mass spectrometry

✍ Scribed by Pruvost, A.; Ragueneau, I.; Ferry, A.; Jaillon, P.; Grognet, J.-M.; Benech, H.


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
109 KB
Volume
35
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for use in pharmacokinetic studies. ENO is light-sensitive and the use of a fully on-line process increased the reliability of the assay. Plasma samples previously mixed with neostigmine bromide to prevent in vitro degradation, and tacrine as internal standard (IS), were directly injected into the SPE/LC/ESI-MS/MS system. MS software piloted the overall system. MS/MS detection of ENO and the IS was performed in the positive ion ESI mode using multiple reaction monitoring. The linear calibration curve for ENO ranged from 25 pg ml -1 to 12.5 ng ml -1 . The limit of quantitation was 25 pg ml -1 with 250 µl of plasma injected. Precision, accuracy and stability tests were within the acceptable range and just one analyst is required to analyze 50 unknown samples a day five days per week, from the preparation of the samples (i.e. thawing and centrifugation) to data processing. A pilot pharmacokinetic study in three healthy volunteers treated with 4.5 mg of ENO (Génésérine3 ® ) showed that the method was suitable for pharmacokinetic studies in humans.


📜 SIMILAR VOLUMES


Quantitative determination of Ecteinasci
✍ Rosing, H.; Hillebrand, M. J. X.; Jimeno, J. M.; Gómez, A.; Floriano, P.; Faircl 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 124 KB 👁 1 views

A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced

High-performance liquid chromatography t
✍ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 88 KB 👁 1 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp