𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of eluent on the ionization efficiency of flavonoids by ion spray, atmospheric pressure chemical ionization, and atmospheric pressure photoionization mass spectrometry

✍ Scribed by Jussi-Pekka Rauha; Heikki Vuorela; Risto Kostiainen


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
199 KB
Volume
36
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 Β΅M for an injection volume of 20 Β΅l. Copyright Β© 2001 John Wiley & Sons, Ltd.


πŸ“œ SIMILAR VOLUMES


Atmospheric pressure photoionization-mas
✍ T. J. Kauppila; T. Nikkola; R. A. Ketola; R. Kostiainen πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 146 KB πŸ‘ 1 views

## Abstract A group of five neurotransmitters with different properties was analyzed using atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization‐mass spectrometry (APCI‐MS). The sensitivity of the techniques for the analytes was tested in six solvents and in posit

Liquid chromatography/mass spectrometry
✍ Antti Leinonen; Tiia Kuuranne; Risto Kostiainen πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 119 KB πŸ‘ 1 views

## Abstract The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods we

Stereochemistry of norditerpenoid alkalo
✍ Wada, Koji; Mori, Takao; Kawahara, Norio πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 148 KB πŸ‘ 2 views

## High -performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (HPLC/APCI-MS) is a very promising approach to structural investigations of positional isomers and stereoisomers. This method was applied successfully to stereoisomeric norditerpenoid alkaloids dif

Characterization of prenylated xanthones
✍ da Costa, Cristina T.; Dalluge, Joseph J.; Welch, Michael J.; Coxon, Bruce; Marg πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 137 KB πŸ‘ 2 views

## Reversed -phase liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) in the positive-ion mode was utilized to analyze crude ether extracts from the root bark of Maclura pomifera, a tree known to have a high content of prenylated xanthones and flavano

The Analysis of Ξ²-Blockers by Capillary
✍ Kathryn A. Hutton; David E. Games πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 285 KB πŸ‘ 2 views

Capillary liquid chromatography/mass spectrometry (LC/MS) is usually performed using electrospray ionization. Atmospheric pressure chemical ionization (APCI) has not been used since the flow rates involved (1-10 Β΅L/min) are too low to effect ionization with a standard APCI source. Using a 320 Β΅m Ψ‹ 1

The Reduction of Chemical Noise in an At
✍ Beat Aebi; Jack D. Henion πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 375 KB

The reduction of chemical noise and the consequent gain in sensitivity on an ionspray interface to an ion-trap mass spectrometer for capillary electrophoresis/mas spectrometry (CE/MS) applications is described. The principal sources of chemical noise were found in ionized airborne contaminants and i