๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Stereochemistry of norditerpenoid alkaloids by liquid chromatography/atmospheric pressure chemical ionization mass spectrometry

โœ Scribed by Wada, Koji; Mori, Takao; Kawahara, Norio


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
148 KB
Volume
35
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

โœฆ Synopsis


High

-performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (HPLC/APCI-MS) is a very promising approach to structural investigations of positional isomers and stereoisomers. This method was applied successfully to stereoisomeric norditerpenoid alkaloids differing in configuration at C-6. APCI-MS allowed the easy and precise control of energy deposition by varying the drift voltage. Comparison of the breakdown curves, observed by changing the potential difference between the first electrode and the second electrode of the APCI ion source, revealed the stereochemical dependence of different fragmentations. Comparison of the APCI spectra showed that the abundance of fragment ions was significantly higher for C-6b alkaloid than for C-6a alkaloid. The axial positions of the corresponding substituents (6-methoxyl and 8-hydroxyl) strongly suggested a 1,3-diaxial interaction effect of the fragmentation. The characteristic fragment ions were formed by the loss of water or acetic acid at position 8, irrespective of the stereochemistry at position 6. The possibility of distinct fragmentation mechanisms depending on the stereochemistry of the precursor ion could be discerned by recording the spectra in a deuterated solvent system of 0.05 M ammonium acetate in D 2 O-acetonitrile-tetrahydrofuran. Loss of D 2 O from the precursor ion gave the fragment ion. This result indicated that the proton of protonation was included in the leaving water molecule. The peak intensity ratio R = [M Y H] Y /[M Y H -H 2 O] Y manifested the stereochemical differentiation of alkaloids at position 6.


๐Ÿ“œ SIMILAR VOLUMES


Atmospheric-pressure Chemical Ionization
โœ Takayuki Nabeshima; Yasuaki Takada; Minoru Sakairi ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 171 KB ๐Ÿ‘ 2 views

An atmospheric pressure chemical ionization (APCI) interface was developed for improved sensitivity in semimicro liquid chromatography/mass spectrometry (LC/MS). This interface consists of a stainless-steel capillary inserted into a bored stainless-steel block, and includes a collision plate perfora

Liquid Chromatography/Mass Spectrometry
โœ Keiji Gamoh; Hiroyuki Abe; Katsuya Shimada; Suguru Takatsuto ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 408 KB ๐Ÿ‘ 2 views

Liquid chromatography/mass spectrometry (LC/MS) with atmospheric pressure chemical ionization has been successfully applied to the simultaneous analysis of free brassinosteroids (polyhydroxylated steroids that serve as plant growth regulators) as their naphthaleneboronates. Of a range of analytical

Characterization of prenylated xanthones
โœ da Costa, Cristina T.; Dalluge, Joseph J.; Welch, Michael J.; Coxon, Bruce; Marg ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 137 KB ๐Ÿ‘ 1 views

## Reversed -phase liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) in the positive-ion mode was utilized to analyze crude ether extracts from the root bark of Maclura pomifera, a tree known to have a high content of prenylated xanthones and flavano

The Analysis of ฮฒ-Blockers by Capillary
โœ Kathryn A. Hutton; David E. Games ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 285 KB ๐Ÿ‘ 2 views

Capillary liquid chromatography/mass spectrometry (LC/MS) is usually performed using electrospray ionization. Atmospheric pressure chemical ionization (APCI) has not been used since the flow rates involved (1-10 ยตL/min) are too low to effect ionization with a standard APCI source. Using a 320 ยตm ุ‹ 1

Atmospheric pressure chemical ionization
โœ P. Manini; R. Andreoli; M. Careri; L. Elviri; M. Musci ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 241 KB ๐Ÿ‘ 2 views

An atmospheric pressure chemical ionization liquid chromatography/mass spectrometry (APCI-LC/MS) system was evaluated for the analysis of cholesterol oxidation products (COPs). High performance liquid chromatography separation of these compounds was performed under reversed-phase chromatographic con