## Abstract The purpose of this work was to validate in phantom studies and demonstrate the clinical feasibility of MR proton resonance frequency thermometry at 1.5 T with segmented gradient‐echo echo planar imaging (GRE‐EPI) sequences during liver tumour radiofrequency (RF) ablation. Classical GRE
Echo planar MR imaging of the liver: Comparison of images with and without motion probing gradients
✍ Scribed by Takao Moteki; Tomoyuki Sekine
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 239 KB
- Volume
- 19
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To determine whether MR images with motion‐probing gradients (MPGs) usefully improve lesion detection in comparison with MR images without MPGs.
Materials and Methods
Echo planar (EP) images without MPGs and with small and intermediate MPGs (gradient factor b = 2, 18, and 188 second/mm^2^, respectively) were acquired for 61 hepatic lesions (21 hepatocellular carcinomas (HCCs), 19 metastases, eight hemangiomas, and 13 cysts). The lesion‐to‐liver signal intensity ratios (SIRs) of these lesions were calculated using EP images with and without MPGs. Qualitative analysis for detection of HCCs and metastases were also performed between the images without MPGs and with small MPGs.
Results
The SIRs of HCCs and metastases for the images with small MPGs were significantly higher than the values for the images without MPGs (P < 0.05), although no significant differences were found in the case of hemangiomas and cysts. In comparison to images without MPGs, images with small MPGs improved lesion detection of three metastases and six HCCs, and worsened lesion detection of two HCCs.
Conclusion
Images with small MPGs may improve HCC and metastasis detection over images without MPGs. J. Magn. Reson. Imaging 2004;19:82–90. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Purpose: To compare the accuracy of fluoro-18-deoxyglucose positron emission tomography (fdg-pet) and dynamic-enhanced magnetic resonance imaging (mri) scans in the diagnosis of liver metastatic lesions from colon and other sources. ## Materials and methods: Thirty consecutive patients with kn
Steady-state free precession imaging is a promising technique for cardiac magnetic resonance imaging (MRI), as it provides improved blood/myocardial contrast in shorter acquisition times compared with conventional gradient-echo acquisition. The better contrast could improve observer agreement and au
## Abstract ## Purpose: To compare the diagnostic accuracy of superparamagnetic iron oxide (SPIO)‐enhanced fluid‐attenuated inversion‐recovery echo‐planar imaging (FLAIR EPI) for malignant liver tumors with that of T2‐weighted turbo spin‐echo (TSE), T2\*‐weighted gradient‐echo (GRE), and diffusion
## Abstract ## Purpose To evaluate image quality and accuracy for the detection of focal hepatic lesions depicted on T2‐weighted images obtained with two high‐resolution free‐breathing techniques (navigator‐triggered turbo spin‐echo [TSE] and respiratory‐triggered TSE) and two standard‐resolution
## Abstract ## Purpose To assess the systematic errors in liver methylene fraction (LMF) resulting from fat–fat interference effects with dual‐ and triple‐echo gradient‐recalled‐echo Dual/Triple GRE) sequences and to test the robustness of these sequences after iron overloading. ## Materials and