## Abstract A method of preparation and flow cytometric analysis of chromosomes from human peripheral lymphocytes is described. The procedure allows a resolution coefficient of variation better than 3% using propidium iodide staining and a commercially available flow cytometer.
DNA analysis of stimulated lymphocytes by automatic sampling for flow cytometry
β Scribed by L. S. Azzolina; G. Stevanoni; G. Tridente
- Publisher
- John Wiley and Sons
- Year
- 1988
- Tongue
- English
- Weight
- 387 KB
- Volume
- 9
- Category
- Article
- ISSN
- 0196-4763
No coin nor oath required. For personal study only.
β¦ Synopsis
A microsample delivery system (MSDS) was tested for automatic flow cytometry (FCM) analysis of DNA synthesis in stimulated human peripheral blood lymphocytes (PBL) cultivated in wells of microtiter plates. After incubation, either for 1-3 days with phytohemagglutinin, concanavalin A, and pokeweed mitogen, or for 7 days with allogenic PBL, the cells, while in the wells, were washed in hypotonic Tris buffer and stained with ethidium bromide-RNAse solution. The results obtained from quintuplicate replicated wells, each of the five containing the same control or stimulated cultures, were reproducible in terms of the number of nuclei counted in each histogram of control, mitogen-stimulated PBL, and mixed lymphocyte cultures (MLC). Using a computer program that superimposes histograms and calculates their differences on the scale of fluorescence intensity, it was possible to quantify the intensity of the response to the mitogenic stimuli. This approach to the study of lymphocyte proliferation offers not only a simpler and faster analysis of DNA synthesis than the method of 3H-thymidine incorporation, but it also allows for the analysis of other FCM parameters, such as forward and 90 degrees light scatter and double fluorescence labelling of PBL nuclei.
π SIMILAR VOLUMES
## Abstract Samples submitted for a suspect of chronic lymphocytic leukemia are the most frequently observed in flow cytometry laboratories. These cases require not only a precise and prompt diagnosis but also an evaluation on the possibility of performing additional prognostic tests. We will propo
The flow cytometric analysis of leucocytes in whole blood is usually performed on samples in which the erythrocytes have been lysed and the leucocytes fixed. Because lysis and fixation reagents have the potential to introduce artefacts, several commercially available reagents were used to prepare no
Cell subsets have been discriminated in cell suspensions derived from 37 human head and neck tumors by means of light scatter, DNA, and cytokeratin flow cytometry (FCM). Cell dispersion was performed overnight at 4Β°C in two different enzyme mixtures, i.e., trypsin/ dithioerythritol and collagenase/l