## Abstract The cure process of a BADGE (diglycidyl ether of bisphenol‐A) resin (Epon 828) and ethylenediamine has been investigated by means of calorimetry and dielectrometry in the microwave region (10^7^–10^10^ Hz) in the temperature range 50 to 70°C. Kinetic data from calorimetry were analyzed
Dielectric monitoring of epoxy cure
✍ Scribed by G. Levita; A. Livi; P. A. Rolla; C. Culicchi
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 534 KB
- Volume
- 34
- Category
- Article
- ISSN
- 0887-6266
No coin nor oath required. For personal study only.
✦ Synopsis
The cure process of mixtures of a DGEBA-type epoxy resin and ethylenediamine, in different molar ratios, was investigated by dielectrometry in a wide frequency range, 103-2 10'' Hz, at three temperatures, 25,60, and 70°C. Two relaxation processes were found whose relevant parameters were obtained by a proper fit procedure. A deeper knowledge and a quantitative description of the observed effects was achieved by analyzing the change of dielectric data caused by the chemical reaction. The change of the dielectric strength of both processes, as well as of other dielectric parameters, reflect the chemical modifications of the system; the permittivity, both static and at microwave frequencies, was linearly related to the conversion. These results support the interpretative model based on the disappearance of dipoles, and confirm the permittivity as a valuable quantity to monitor the kinetics of the reaction.
📜 SIMILAR VOLUMES
## Abstract Dielectric measurements were performed in ‘real‐time’ at several temperatures to follow polymerization reactions on blends of a diglycidyl ether of bisphenol A (DGEBA) epoxy resin with 4, 4′‐diaminodiphenylmethane (DDM) hardener and different amounts of polyoxypropylenetriamine (POPTA)
## Abstract Viscosity is an important process variable that should be monitored and controlled to ensure the consistent and reliable production of graphite‐fiber‐reinforced composite parts by the autoclave/vacuum bag process. Unfortunately, no technique is currently known for the direct measurement