Development of a precolumn capillary liquid chromatography switching system for coupling to mass spectrometry

✍ Scribed by J. A. Pascual; G. J. ten Hove; A. P. J. M. de Jong


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
517 KB
Volume
8
Category
Article
ISSN
1040-7685

No coin nor oath required. For personal study only.

✦ Synopsis


A column switching system was developed for capillary liquid chromatography using a robust low back pressure precolumn (PC) for fast loading of large sample volumes. After loading, trapped analytes are transferred to the capillary separation column by a backflush linear gradient flow. The PC contained a small quantity of reversed-phase C18 material prepared in poly etheretherketone (PEEK) tubing, which is capped at both sides by means of high-performance liquid chromatography (HPLC) in-line filters. Gradient backflush elution provided an effective means for preconcentration and refocusing of analytes of different nature and polarity. The technique showed a clearcut improvement in separation efficiency as compared with switching systems using forward flow elution of the PC. The system was connected to continuous flow Fast Atom Bombardment (FAB)/rnass spectroscopy for the analysis of steroids and peptides. Salts and polar compounds present in the sample were removed by extensive washing of the precolumn with an appropriate water percentage before their elution and separation. The preconcentration of diluted samples on the PC gave an increase in sensitivity of approximately two orders of magnitude as compared with wide-bore HPLC-CF (continuous flow) FAJ3 using effluent splitting.


πŸ“œ SIMILAR VOLUMES


Development of a nano-electrospray mass
✍ James N. Alexander IV; Gary A. Schultz; Janet B. Poli πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 226 KB πŸ‘ 2 views

A Fisons Quattro I electrospray ionization (ESI) source has been modified to produce stable electrospray ion currents at flow rates as low as 50 nL/min. The original counter electrode and skimmer cone lens of the Fisons ESI source have been replaced with a spherical cone lens. This improved source p

Packed capillary column liquid chromatog
✍ Benita Hyllbrant; Niklas Tyrefors; Bengt LΓ₯ngstrΓΆm; Karin E. Markides πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 89 KB πŸ‘ 2 views

When packed capillary columns are coupled to electrospray mass spectrometry, care must be taken to reduce the dead volumes of the detector connections. In this work, the coupling between the column and the detector was made with a 20-m i.d. fused silica capillary which was inserted in the electrospr