A sensitive and specific LC/MS/MS method for the determination of L-hyoscyamine was developed and validated over the linearity range 20-500 pg ml-1 with 1.0 ml of plasma using scopolamine as the internal standard. The API III-Plus LC/MS/MS was operated under the multiple reaction monitoring mode usi
Development and validation of an LC-MS-MS method for the determination of terfenadine in human plasma
β Scribed by A. Xu; K. Linderholm; L. Peng; J. Hulse
- Publisher
- Elsevier Science
- Year
- 1996
- Tongue
- English
- Weight
- 343 KB
- Volume
- 14
- Category
- Article
- ISSN
- 0731-7085
No coin nor oath required. For personal study only.
β¦ Synopsis
A sensitive LC-MS-MS method capable of quantifying terfenadine at levels down to 100 pg ml-1 in human plasma is reported. The method was validated over a linear range from 0.1 to 5.0 ng ml-1 using a liquid-liquid extraction with a deuterium-labelled internal standard. The between-run precision and accuracy of the calibration standards were 2.6-6.0% RSD and -2.0 to +2.2% relative error (RE). The between-run and within-run precision and accuracy of quality control samples (0.3, 1.5 and 3.5 ng ml-1) were 1.0-5.9% RSD and +1.7 to +6.3% RE. This method was applied to the analysis of human plasma samples.
π SIMILAR VOLUMES
## Abstract The anticancer drug capecitabine and its metabolites [including the active metabolite 5βfluorouracil (5βFU)] display high pharmacokinetic interβpatient variability. Such variability, which may lead to treatment failure or toxicity, could need drug concentration measurement to individual