## Abstract Styraxlignolide A is a pharmacologically active ingredient isolated from __Styrax japonica__ Sieb. et Zucc. A rapid, selective, and sensitive liquid chromatographic method with electrospray ionization tandem mass spectrometry was developed for use in the quantification of styraxlignolid
Development and validation of a liquid chromatography/electrospray ionization tandem mass spectrometry method for the quantification of latanoprost free acid in rabbit aqueous humor and ciliary body
โ Scribed by Alessio Zammataro; Claudine Civiale; Rosaria Saletti; Salvatore Foti
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 296 KB
- Volume
- 46
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.2004
No coin nor oath required. For personal study only.
โฆ Synopsis
A rapid, selective and sensitive method for quantification of latanoprost free acid in rabbit aqueous humor (AH) and ciliary body (CB) using reverse phaseโhigh performance liquid chromatography coupled with electrospray ionization (ESI)โmass spectrometry/mass spectrometry has been developed and validated. Quantification in AH and CB was achieved by stable isotope dilution employing tetraโdeuterated analog of latanoprost free acid, used as internal standard. Sample preparation was based on protein precipitation with methanol in AH, and on liquid extraction with a mixture of ethyl acetate and isopropanol 60:40 (v/v) in CB. Elution was achieved on an octylsilica (C8) column, using an isocratic elution method. Detection was performed on a triple quadrupole mass spectrometer, using ESI in positive ion selected reaction monitoring mode. Calibration curves were linear in the validated concentration ranges of 10โ160โng/mL in AH and 80โ1280โng/g in CB. The accuracy and precision values, obtained from three different sets of quality control samples, each analyzed in triplicate on three different days, were within the generally accepted criteria for analytical methods (< 15%). The limit of detection was 30.66โpg/mL in AH and 237.75โpg/g in CB. The assay proved to be accurate and precise when applied to the in vivo study of latanoprost free acid in rabbit AH and CB after single administration of an eye drops containing latanoprost. Copyright ยฉ 2011 John Wiley & Sons, Ltd.
๐ SIMILAR VOLUMES
A sensitive method for the determination of a prokinetic peptide, KW-5139 (Leu 13 -motilin), in rat plasma has been developed utilizing liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS). KW-5139 was separated by reversed-phase HPLC, with a mixture of 75 mM ammonium formate