𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development and validation of a liquid chromatography and ion spray tandem mass spectrometry method for the quantification of artesunate, artemether and their major metabolites dihydroartemisinin and dihydroartemisinin-glucuronide in sheep plasma

✍ Scribed by Urs Duthaler; Jennifer Keiser; Jörg Huwyler


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
228 KB
Volume
46
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Recently, promising fasciocidal activities of artesunate and artemether were described in rats and sheep. Therefore, a liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed to quantify artesunate, artemether and their metabolites dihydroartemisinin and dihydroartemisinin‐glucuronide in sheep plasma. Protein precipitation with methanol was used for sample workup. Reversed‐phase high‐performance liquid chromatography (HPLC) was performed using an Atlantis C18 analytical column with a mobile phase gradient system of ammonium formate and acetonitrile. The analytes were detected by MS/MS using selected reaction monitoring (SRM) with electrospray ionisation in the positive mode (transition m/z 267.4 → 163.0). The analytical range for dihydroartemisinin, dihydroartemisinin‐glucuronide and artesunate was 10–1000 ng/ml and for artemether 90–3000 ng/ml with a lower limit of quantification of 10 and 90 ng/ml, respectively. Inter‐ and intra‐day accuracy and precision deviations were < 10%. Consistent relative recoveries (60–80%) were observed over the investigated calibration range for all analytes. All analytes were stable in the autosampler for at least 30 h (6 °C) and after three freeze and thaw cycles. The validation results demonstrated that the LC–MS/MS method is precise, accurate and selective and can be used for the determination of the artemisinins in sheep plasma. The method was applied successfully to determine the pharmacokinetic parameters of artesunate and its metabolites in plasma of intramuscularly treated sheep. Copyright © 2011 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


A sensitive and selective liquid chromat
✍ S. Sabarinath; M. Rajanikanth; K. P. Madhusudanan; R. C. Gupta 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 194 KB 👁 1 views

## Abstract A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of α‐,β‐arteether (α‐,β‐AE) and its metabolite α‐dihydroartemisinin (DHA) in monkey plasma using

Comprehensive liquid chromatography–ion-
✍ Sílvia Mas; Olga Jáuregui; Fernando Rubio; Anna de Juan; Romà Tauler; Sílvia Lac 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 486 KB

## Abstract We propose an instrumental method based on liquid chromatography coupled to negative ion‐spray ionization (ISP(−)) tandem mass spectrometry (MS/MS), for the simultaneous analysis of eight hydroxylated brominated diphenyl ethers (OH‐PBDEs) in four different environmental matrices (soil,

Validation and application of a method f
✍ David L. Heavner; Joel D. Richardson; Walter T. Morgan; Michael W. Ogden 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 292 KB 👁 1 views

An SPE-LC-MS/MS method was developed, validated and applied to the determination of nicotine and five major metabolites in human urine: cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide, cotinine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide. A 500 microL urine sample was pH-adju

Development and validation of a liquid c
✍ Alessio Zammataro; Claudine Civiale; Rosaria Saletti; Salvatore Foti 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 296 KB

A rapid, selective and sensitive method for quantification of latanoprost free acid in rabbit aqueous humor (AH) and ciliary body (CB) using reverse phase‐high performance liquid chromatography coupled with electrospray ionization (ESI)‐mass spectrometry/mass spectrometry has been developed and vali