Development and validation of a highly sensitive and robust LC-ESI-MS/MS method for simultaneous quantitation of simvastatin acid, amlodipine and valsartan in human plasma: application to a clinical pharmacokinetic study

โœ Scribed by Addepalli V. Ramani; Pinaki Sengupta; Ramesh Mullangi


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
545 KB
Volume
23
Category
Article
ISSN
0269-3879

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Development and validation of a highly s
โœ Kishore Kumar Hotha; D. Vijaya Bharathi; B. Jagadeesh; L. K. Ravindranath; K. N. ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 311 KB ๐Ÿ‘ 3 views

## ABSTRACT A highly sensitive, specific and simple LCโ€MS/MS method was developed for the simultaneous estimation of dexlansoprazole (DEX) with 50โ€‰ฮผL of human plasma using omeprazole as an internal standard (IS). The APIโ€4000 LCโ€MS/MS was operated under multiple reactionโ€monitoring mode using elect

Development and validation of a highly s
โœ Abhijeet Y. Deshpande; Sandip Gurav; Ravindra Punde; Vishal Zambre; Rahul Kulkar ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 882 KB

## Abstract A highly sensitive and specific LCโ€MS/MS method has been developed for simultaneous quantification of ethionamide and ethionamide sulfoxide in human plasma (300โ€‰ยตL) using prothionamide as an internal standard (IS). Solidโ€phase extraction was used to extract ethionamide, ethionamide sulf

Highly sensitive LC-MS/MS-ESI method for
โœ Kuldeep Sharma; Murugesh Kandaswamy; Chandan Mithra; Ashok Kumar Meena; Sanjeev ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 628 KB

## ABSTRACT A highly sensitive and specific LCโ€MS/MSโ€ESI method was developed for simultaneous quantification of albenadazole (ABZ) and ricobendazole (RBZ) in rat plasma (50โ€‰ฮผL) using phenacetin as an internal standard (IS). Simple protein precipitation was used to extract ABZ and RBZ from rat plas

Development and validation of a sensitiv
โœ D. Vijaya Bharathi; Kishore Kumar Hotha; P. V. Vidya Sagar; S. Sirish Kumar; A. ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 396 KB ๐Ÿ‘ 2 views

## Abstract A highly sensitive and specific LCโ€MS/MS method has been developed and validated for the estimation of pramipexole (PPX) with 500ย ยตL human plasma using memantine as an internal standard (IS). The APIโ€4000 was operated under multipleโ€reaction monitoring mode (MRM) using the electrospray